www.fmiproducts.com
122280-01E6
SPECIFICATIONS
GAS RATING - NATURAL
BBM-36N-TKA BBM-42N-TKA BBM-50N-TKA
Max. Input Rating: 52,000 Btu/Hr 56,000 Btu/Hr 60,000 Btu/Hr
Manifold Pressure: 3.5" WC (.87 kPa) 3.5" WC (.87 kPa) 3.5" WC (.87 kPa)
Min. Supply Pressure: 4.5" WC (1.12 kPa) 5.0" WC (1.24 kPa) 5.0" WC (1.24 kPa)
Max. Supply Pressure: 10.5" WC (2.66 kPa) 10.5" WC (2.66 kPa) 10.5" WC (2.66 kPa)
Orice Size: # 26 # 23 # 18
GAS RATING - PROPANE/LP
BBM-36P-TKA BBM-42P-TKA BBM-50P-TKA
Max. Input Rating: 46,000 Btu/Hr 52,000 Btu/Hr 57,000 Btu/Hr
Manifold Pressure: 10" WC (2.49 kPa) 10" WC (2.49 kPa) 10" WC (2.49 kPa)
Min. Supply Pressure: 11" WC (2.74 kPa) 11" WC (2.74 kPa) 11" WC (2.74 kPa)
Max. Supply Pressure: 13" WC (3.23 kPa) 13" WC (3.23 kPa) 13" WC (3.23 kPa)
Orice Size: # 46 # 44 # 43
*For the purpose of input adjustment.
Figure 2 - Possible Locations for
Installing Appliance
INTERNAL WALL
INSTALLATION
CORNER
INSTALLATION
FULL
PROJECTION
INSTALLATION
FLUSH
INSTALLATION
SELECTING LOCATION
To determine the safest and most efcient
location for your appliance, you must take into
consideration the following guidelines:
1. The location must allow for proper clear-
ances (see clearance information on
page 10).
2. Consider a location where heat output
would not be affected by drafts, air con-
ditioning ducts, windows or doors.
3. A location that avoids the cutting of joists
or roof rafters will make installation easier.
Figure 1 shows a plan view of a few com-
mon locations.
Flush installations are recommended where
living space is limited or at a premium and
since the space required to enclose the ap-
pliance would be located beyond an outside
wall, this would also reduce the cutting of
joists, roof rafters and such. Check local
codes for any restrictions.
can extend any
distance into the room. A projection may
be ideal for a new addition on an existing,
nished wall.
Corner installations make use of space
that may not normally be used and provides
a wider and more efcient range for radiant
heat transference.
provide a discreet
option for room separation and can also be
ideal as an addition to an existing wall.