FMI BVC-50Y Indoor Fireplace User Manual


 
www.fmiproducts.com
122280-01E 33
CLEANING AND MAINTENANCE
WARNING: Installation and
-
-

each use and at least annually
    

   
-


-



WARNING: Turn off gas and

appliance.
 
    


GLASS DOORS
Glass doors are optional with the replace.
When replace is in operation, doors must be
fully opened or fully closed position only or a
re hazard may be created (see Figure 41).
A replace equipped with glass doors oper-
ates much differently than a replace with an
open front. A replace with glass doors has a
limited amount of air for combustion.
Excessive heat within replace can result if
too large a re is built or if combustion air
gate is not completely open. The following tips
should be followed to assure that both re-
place and glass doors retain their beauty and
function properly. Both ue damper and glass
doors must be fully opened before starting re.
This will provide sufcient combustion air and
maintain safe temperatures in rebox.
WARNING: Fireplaces
   
    
doors fully opened or doors fully


   

CLEANING GLASS
Clean glass with any commercial glass
cleaner or soap and water. Do not use any
abrasive material to clean glass. Do not clean
glass with any cool water if glass is still hot
from the re and smoke.
A gas line or gas log lighter may be installed
for the purpose of installing a vented or vent-
free decorative gas appliance incorporating an
automatic shutoff device and complying with
the Standard for Decorative Gas Appliances
for Installation in Vented Fireplaces, ANSI
Z21.60 or American Gas Association draft
requirements for Gas Fired Log Lighters for
Wood Burning Fireplaces, Draft NO. 4 dated
August, 1993.
Figure 41 - Bi-Fold Glass Doors
Doors Fully Closed
Fireplace Front
Doors
Fully Opened
Fireplace Front