13
b
1
2
3
4
Fig. 2.6b
Fig. 2.6a
REGULATOR
COVER
Pressure
regulator
CONVERSION TO LP/PROPANE GAS
Every range is provided with a set of injectors for the various types of gas.
Select the injectors to be replaced according to the “INJECTORS TABLE”.
The nozzle diameters, expressed in hundredths of a millimetre, are marked on the
body of each injector.
SETTING THE PRESSURE REGULATOR (fig. 2.6b)
The pressure regulator is accessible by removing the bottom drawer; the pressure
regulator is positioned on the rear left side of the range. To remove the drawer
proceed as per figure 2.6a.
To set the pressure regulator:
1. Unscrew the regulator cover;
2. Unscrew the A component, reverse and screw it according to the LP/PROPANE
regulation.
2