– 8 –
ENTRY/EXIT DELAYS
Exit Alarms
To minimize false alarms
sent to the alarm
monitoring company,
your system may have
been programmed for this
feature. Ask your installer
if "Exit Alarm" is active for
your system.
Exit Alarm Active
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior zone is
faulted when the exit delay ends (e.g., exit door left open), the system sounds an alarm and
starts the entry delay timer. If you disarm the system before the entry delay ends, the alarm
sound stops and the message "CANCEL ALARM" or "CA" is displayed on the keypad, along
with a zone number indicating the faulted zone. No message is sent to the alarm monitoring
company. To clear the exit alarm condition, the open zone must be made intact; to clear the
display, enter your code plus OFF.
If you do not disarm the system before the entry delay ends, and an entry/exit door or interior
zone is still open, the alarm sound continues and an "exit alarm" message is sent to the alarm
monitoring company. The message ""EXIT ALARM" or "EA" is displayed on the keypad, along
with a zone number indicating the faulted zone. To stop the alarm, the system must be
disarmed (your code plus OFF); to clear the display, enter your code plus OFF a second time.
An “exit alarm” also results if an entry/exit door or interior zone is faulted within two minutes
after the end of the exit delay.
COMMON ZONE OPERATION
Ask your
installer if a common
zone was assigned.
Your system may have been set up to use a common zone, which is an area shared by users of
both partitions, such as a foyer or lobby. If so, please note the following:
• The common zone will sound and report alarms only when both partitions are armed. If only
one partition is armed, the system ignores faults on the common zone.
• Either partition may arm its system if the common zone is faulted, but once armed, the other
partition will not be able to arm unless the common zone is first bypassed or the fault is
corrected.
• If either partition is armed and the other is in chime mode, the common zone will not chime.
The common zone will chime if both partitions are disarmed and either is in chime mode.
• Faults on the common zone are displayed on keypads in both partitions.
• Either partition can clear and restore the common zone after an alarm.