Field Controls UV-E Air Cleaner User Manual


 
Page 6
III. BULB MOUNTING BRACKET SELECTION AND INSTALLATION
The UV-AIRE
TM
units come with an angled mounting bracket and flat mounting bracket to position the bulb either
straight or at an angle. Choose one or the other bracket method best suited for your needs. Refer to the
configurations chart below when making your selection.
A
NGLED LAMP MOUNTING BRACKET SPECIFICATIONS
Use the specifications below to determine allowable clearances for proper mounting of the UV-Aire™ unit on the duct.
LAMP OFFSET DIMENSIONS
Lamp
Length
A B
Lamp Part
No.
12” 8-1/2 6-1/2 46365401
18” 13-1/2 10-5/16 46365402
28” 21-3/8 16-1/4 46365403
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause
p
ermanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum.
A
void touching the glass portion of the lamp with your hands.
Standard 90° Installation
(Flat Bracket)
(Fits a minimum 18” Duct)
Patent Pending 45°
Installation
(Angled Bracket)
(Fits a minimum 14” Duct)
UV-Aire™ Configurations
Diagram
A
Good Better
Standard 90° Installation
(Flat Bracket)
(Fits a minimum 12” Duct)
Patent Pending 45°
Installation
(Angled Bracket)
(Fits a minimum 8” Duct)