15. Determine whether to use flat or angled bracket. (Refer to UV-Aire Configurations in Section III for aid in this
decision)
a. Flat Bracket Installation
i. Remove the two hex nuts and flat bracket from included bagged
hardware.
ii. Install the flat bracket and secure to the unit base with the hex nuts
provided. (See Figure 10)
b. Angled Bracket Installation
NOTE: For angled bracket mounting, refer to specifications outlined by Diagram
A for mounting distances in the “Angled Lamp Mounting Bracket Specifications”
in section III.
i. Remove the two hex nuts and angled bracket from included bagged
hardware.
ii. Install the angled bracket and secure to the unit base with the hex nuts
provided. (See Figure 11) The angle bracket may be mounted in 4
positions allowing the bulb to either be angled up and down or left to
right, depending upon duct design. (Figures A-D)
NOTE: Be sure to note location of lamp hole in bracket relative to unit
base.
L
AMP INSTALLATION
This unit is listed for use with Field Controls’ lamps ONLY. You will need to determine
proper lamp selection based on duct size and desired configuration. (Refer to
configuration table on page 6 of this manual)
16. Remove tag and alcohol from lamp. Wipe off lamp being sure not to touch lamp
with bare hands. The oils in your hands may cause the lamp to prematurely
expire.
17. Insert lamp through hole in bracket until lamp is snug against the bracket. (See
Figure 12)
WARNING: Never expose eyes or skin to UVC light from any source. Looking directly at the UVC light may cause
p
ermanent eye damage or blindness. Never operate the UV-Aire™ Air Purifying System out of the plenum.
A
void touching the glass portion of the lamp with your hands.
Figure 10
Figure 11
Figure 12
Figure A
Figure B
Figure C Figure D