Enviro EG 28 B Indoor Fireplace User Manual


 
TABLE OF CONTENTS
Safety Precautions 2
Code Approvals 3
Deciding where to locate your stove 4
Venting 6
Installation of Log Sets and Embers 8
Operating Instructions 9
Maintenance and Technical 10
Trouble Shooting 11
Gas Line Connection 12
Electrical 13
Parts and Accessories 14
Fuel Type Conversion 15
Warranty 16
Parts List 17
Exploded Views 18-19
Installation Data Sheet 20
CODE APPROVALS
This Vented appliance draws all of its combustion air from the dwelling and must be vented using listed B or L
vent. May also be vented through a conventional chimney using a chimney liner kit.
This appliance have been tested by INTERTEK TESTING SERVICES (WH) and found to comply with the
established standards for a VENTED GAS FIREPLACE HEATER in CANADA and the USA as follows:-
LISTED GAS FIRED VENTED ROOM HEATER ( EG 28 BV. Nat. & LPG. )
TESTED TO: ANSI Z21.88-1998 CSA 2.33-M98 VENTED GAS FIREPLACE HEATER
CGA 2.17-M91 GAS FIRED APPLIANCES FOR USE AT HIGH ALTITUDE
SPECS:
ENVIROGAS EG 28 B VENT UNITS;
have all been certified for use with either natural or propane gases. (see control panel and rating label.)
are not for use with solid fuels.
must not be connected to a chimney flue serving a separate solid-fuel burning appliance.
are approved for bedroom or bedsitting room.
(IN CANADA: must be installed with a listed wall thermostat)
(IN USA: see current ANSI Z223.1 for installation instructions.)
must be installed in accordance with local codes if any. If none exist, use current installation code CAN/CGA
b149 in Canada or ANSI Z223.1 / NFPA 54 in the USA.
must be properly connected to an approved venting system.
are approved for installation on combustible materials.
are not approved for closet or recessed installations.
FOR INSTALLATIONS ABOVE 2000 FEET (610 m).
In Canada these appliances must have the input de-rated by 10% as per the gas code.
In the USA these appliances must have the inputs de-rated by 4% for every 1000 feet (305m) above sea level.
ASSEMBLY INSTRUCTIONS
Remove the packaging from the appliance, check to make sure there is no damage. If damage is found, PREPARATION FOR
INSTALLATION
Please report it to both the carrier and your dealer as soon as possible.
Before beginning, carefully check the glass door and the log set
3