Enviro EF3 Stove User Manual


 
10
Installation of firebox backing:
• Install the side panels in place. Insert center panel, hold the panels in place
• Install the top rod by sliding it into one side panel then across into the other panel. Screw rod in
place.
• Re-install steel brick liner and screw in place.
• Replace top baffle
EXHAUST VENT (season)
The products of combustion will contain small particles of flyash. The flyash will collect in the exhaust
venting system and restrict the flow of the flue gases. Incomplete combustion, such as occurs during
startup, shutdown, or incorrect operation of the room heater will lead to some soot formation which
will collect in the exhaust venting system. The exhaust venting system should be inspected at least
once every year or after two tons of pellets to determine if cleaning is necessary. We recommend
contacting your dealer for professional cleaning. To remove dust from the vent pipe, tap lightly on the
pipe to dislodge any loose ash. Open the bottom of the “T” to dump the ash, then vacuum as much of
the ash out of the vent pipe as possible.
BLOWER MECHANISMS (season)
Unplug the stove then open the right/left side panels to access the two blowers. Vacuum all dust from
motors. Only the convection blower motor (on the right side of the stove) will require lubrication. The
convection motor has two lubrication holes on it. Use two drops of SAE 20 light oil to lubricate every six
months. Excess oil may damage the motor. The exhaust blower’s motor has sealed bearings, DO NOT
lubricate this motor.
DOOR GLASS (It is recommended that your dealer replace the glass if broken.)
The door glass is made of 5 mm thick, high temperature PYROCERAMIC. To replace the glass, unscrew
and remove the four glass retainers. Remove the glass and any broken pieces. High temperature
fiberglass tape should be used around the glass. Replace the glass, center the glass assembly in the
frame, then screw the glass retainers back to the frame. The use of substitute materials is prohibited use
only part EF-062.
POST SEASON CLEAN-UP
Once you are finished using the pellet appliance for the season, unplug the stove for added electrical
protection. It is very important that the stove be cleaned and serviced as stated above.
CLEANING PLATED SURFACES
Please clean all fingerprints off of all gold parts, with denatured alcohol on a soft cloth, before firing the
unit each time. Fingerprints, etc. can become permanently etched into the gold if not removed before
operating the pellet heater.
BRICK PANEL
The paint on the steel brick panel may peel. This is due to extreme conditions applied to the paint and is
in no way covered by warranty.
Routine Cleaning and Maintenance