Enviro DV36 Indoor Fireplace User Manual


 
8
Operating Instructions
For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
E) Turn on all electrical power to the unit.
NOTE: Check that all burner holes are lit.
TO TURN GAS FIREPLACE OFF:
Flip switch to OFF to turn off burners only.
If the replace is to be turned off for the season,
or for servicing, turn the gas shut off valve to
OFF. DO NOT FORCE IT. If the unit is going to
be serviced, turn off the electrical power to the
unit as well.
NOTE: When the unit is turned on for the rst time, it should be turned onto high, with the fan OFF,
for the rst two to four hours. This will cure the paint, logs, gasket material, and other products used
in the manufacturing process. It is advised that a door or window be opened as the unit will start to
smoke, which can irritate some people. After the unit has gone through the rst burn, turn the unit OFF,
including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good
gas replace glass cleaner, available at your local Enviro dealer. See “MAINTENANCE AND SERVICE; GLASS
DOOR REMOVAL and “MAINTENANCE AND SERVICE; CLEANING THE GLASS.”
BLOWER SPEED (OPTIONAL):



Figure 5. Control Panel
Figure 6. Fan Control
 




BURNER LIGHTING:
A) Make sure the pilot is lit.
B) Turn gas control knob COUNTER CLOCKWISE to ON.
C) Flip the burner switch to ON.
D) Turn HI/LO knob to the desired ame height.
The blower will come on only when the replace is up to temperature
(approximately 20 minutes). The speed of the fan can be changed by turning the
fan control knob. To turn the blower off, turn the knob COUNTER CLOCKWISE
until it “clicks” off (Figure 6).
It is advisable not to operate the blower below
1
/3 speed as it puts a strain on
the windings of the blower and running the blower at lower speeds could also
cause premature fan failure.
NORMAL SOUNDS DURING OPERATION:
Table 1: Normal Sounds
Component Sound & Reason
DV36 & Fascia Creaking when heating up or cooling down.
Burner Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor Clinking when it senses to turn the blower on or off.
Pilot Flame Quiet whisper while the pilot ame in on.
Blower / Fan Air movement that increase and decreases with the speed of the blower. The
blower is pushing the heat from the replace into the room.
Gas Control Valve Dull click when turning on or off, this is the valve opening and closing.