Enviro DV36 Indoor Fireplace User Manual


 
Figure 23. Combustible Mantel Clearances for Fascia or
Insets.
Initial Installation
QUALIFIED INSTALLERS ONLY
16
A shelf may be installed above the unit. We
recommend that no heat sensitive items or
components be placed on the shelf (see
Figure 22).
MANTEL CLEARANCES:
It is not necessary to install a mantel, but if one is desired it is important to follow the guidelines.
Note: Louvers have different mantel clearances than when fascia or insets are installed.
Table 3: Mantel clearances.
Louvers Only Fascia or Insets
Top of unit to horizontal framing 3” (7.6 cm) 3” (7.6 cm)
Top of unit to bottom of 3” (7.6 cm) mantel 12” (30.5 cm)
Top of unit to bottom of 3” (8.9 cm) mantel 8” (20.3 cm
Top of unit to bottom of 10” (254 mm) mantel 10” (25.4 cm 14” (35.6 cm)
Top of unit to bottom of ” (19 mm) facing board 6” (15.2 cm) 6” (15.2 cm)
3"
(76mm)
Top of unit
Combustible
front face
Combustible board
Figure 22. Combustible Shelf Clearance.
To Ceiling
37”
Figure 21. Raised Fireplace with no Hearth
Even though the DV36 can be installed at oor
level without a hearth, there are a few options
with raised replaces: raised with a oor level
hearth (Figures 19), raised with a raised hearth
(Figures 20), or raised with no hearth (Figures 21).
If the replace is raised, it cannot be placed within
37 inches (1.04 m) of the ceiling. When installing
a raised replace, it is imperative that the support
stand is strong enough to hold the weight of the
replace and venting.
3"
(76mm)
12"
(305mm)
6"
(152mm)
14"
(356mm)
Top of unit
3” (76mm) mantle
10" (254mm) mantle
Combustible front face
3
/4" (19mm) facing board