Operating Instructions
For Your Safety, Read Safety Precautions And
Lighting Instructions Before Operating
TURN OFF UNIT:
Flip switch to OFF to turn off burners only.
If the replace is to be turned off for the season, or for servicing, turn the gas shut off valve to OFF. If
the unit is going to be serviced, turn off the electrical power to the unit as well.
NOTE: When the unit is turned on for the rst time, it should be turned onto high, with the fan OFF,
for the rst two to four hours. This will cure the paint, logs, gasket material, and other products used
in the manufacturing process. It is advised that a door or window be opened, as the unit will start to
smoke, which can irritate some people. After the unit has gone through the rst burn, turn the unit OFF,
including the pilot, and let the unit get completely cold. Then remove the glass and clean it with a good
gas replace glass cleaner, available at your local Enviro dealer. See “DOOR REMOVAL” and “CLEANING THE
GLASSsections.
BLOWER SPEED:
The blower will come on only when the replace is up to temperature (approximately
20 minutes). Turning the fan control knob will change the speed of the fan. To turn
the blower off, turn the knob COUNTER-CLOCKWISE until it “clicks” off (Figure 6).
It is advisable not to operate the blower below
1
/3 speed as it puts a strain on the
windings of the blower and running the blower at lower speeds could also cause
premature fan failure.
NORMAL SOUNDS DURING OPERATION:
Table 2: Normal Sounds.
Component Sound & Reason
Focus & Fascia Creaking when heating up or cooling down.
Burner Light pop or poof when turned off; this is more common with LP units.
Temperature Sensor Clinking when it senses to turn the blower on or off.
Pilot Flame Quiet whisper while the pilot ame in on.
Blower / Fan Air movement that increase and decreases with the speed of the blower. The
blower is pushing the heat from the replace into the room.
Gas Control Valve Dull click when turning on or off, this is the valve opening and closing.



Figure 6: Fan control.
ADJUSTING VENTURI AIR SETTINGS:
There is one venturi adjustment.
Use this venturi adjustment lever, shown in Figure 7, to
achieve a proper and efcient ame.
Adjust lever until the ame pattern is similar to Figure
37. Suggested pull out distances are ” (13 mm)
minimum for Natural Gas and ” (22 mm) minimum
for Propane.
Pull out the venturi adjustment to increase primary air at the venturi tube.
Push in the venturi adjustment to decrease primary air at the venturi tube.
Figure 7: Adjusting the venturi air setting.