Enviro C-11212 Stove User Manual


 
NOTE: If the Sienna unit is pulled
out of its installation, and the vent
air intake system is disconnected
for any reason, ensure that the
vent-air intake pipes are re-sealed
with high-temperature sealant
or silicone and reconnected with
three (3) sheet metal screws
evenly spaced.
IMPORTANT: The Sienna is to be
vented only with vertical venting
– no horizontal.
2ft (0.6m)
Minimum
3ft (0.9m)
Minimum
Within
10ft (3m)
Roof ridge or
any other portion
of a building
Figure 21: Roof Clearances.
Table 3: Vent termination clearances
Minimum Clearance Description
3 ft (0.9 m)
Clearance above the highest point where it passes through a roof surface, refer
to Figure 21.
24 in (0.6 m)
Clearance above a roof ridge, any other portion of a building, or any other ob-
struction within a horizontal distance of 10 feet (3 m), refer to Figure 21.
5 ft (1.5 m)
Clearance for a vent or chimney above either the highest connected appliance
drafthood outlet, or ue collar.
6 ft (1.83 m) Clearance to mechanical air supply inlet.
3ft (0.9m) Clearance to each side of center line extended above meter/regulator assembly.
6 ft (1.83 m) Radial clearance around service regulator vent outlet.
12 in (30 cm) Clearance above grade, verandah, porch, deck, or balcony.
3 ft (0.9 m)
Clearance to a building opening or combustion air inlet of another appliance,
except with the approval of the authority having jurisdiction for the following
reduced clearances.
9 in (0.23 m) Exception for inputs up to and including 50,000 Btu/h (15kW)
12 in (0.3 m)
Exception for inputs exceeding 50,000 Btu/h (15kW) but not exceeding 100,000
Btu/h (30kW)
ZERO CLEARANCE FIREPLACE INSTALLATION:
The metal oor of the ZC solid fuel rebox can be removed to allow the installation of the insert. THE
CLEARANCE TO COMBUSTIBLE MATERIAL UNDER THE INSERT IS ” (13mm). YOU MUST USE THE
LEVELING LEGS TO RAISE THE INSERT A MINIMUM OF ” (13mm) IF THE UNIT IS TO BE INSTALLED
ON COMBUSTIBLE MATERIAL. The sidewalls and top structure of the solid fuel rebox cannot be altered
with the exception of removable dampers and bafes. THE ORIGINAL FIREPLACE MAY NEVER BE
RETURNED TO SOLID FUEL USE IN THIS CONDITION.
IMPORTANT: If the factory-built replace has no gas access hole(s) provided, an access hole of 1.5 inch
(37.5 mm) or less may be drilled through the lower sides or bottom of the rebox in a proper workmanship
like manner. This access hole must be plugged with non-combustible insulation after the gas supply line
has been installed. Cutting any sheet-metal parts of the replace, in which the gas replace insert is to
be installed, except as tested for the oor is prohibited.
Initial Installation
QUALIFIED INSTALLERS ONLY
17