Specifications
DIMENSIONS:


























Height: 24
1
/16 inches (611 mm)
Width: 19
1
/16 inches (484 mm)
Depth: 15  inches (397 mm)
Center of ue to ground without leveling legs:
18  inches (467 mm)
Center of ue to ground with leveling legs (approx.):
19 inches (483 mm)
Figure 1. Dimensions of the Ascot.
CLEARANCES TO COMBUSTIBLES:
A) Sidewall to unit 10 inches (254 mm)
B) Backwall to unit 2 inches (64 mm)
C) Corner to unit 2 inches (64 mm)
D) Ceiling bottom of unit 60 inches (1524 mm)
E) Floor 0 inches (0 mm)
Must have hearth pad if installed on a carpeted surface.
If this unit is installed in an alcove the alcove must meet
these minimum dimensions:
Width 48 inches (1219 mm)
Height 60 inches (1524 mm)
Maximum Depth 24 inches (610 mm)
WARNING: Operation of this heater when not connected to a properly installed and maintained venting
system or tampering with the vent safety shutoff system can result in carbon monoxide (CO) poisoning
and possible death.

 
 

 
 
Figure 2: Clearances to combustibles.