Enviro 50-029 Indoor Fireplace User Manual


 
26
Secondary Installation
CAUTION: NEVER OPERATE THIS APPLIANCE WITH THE DOOR REMOVED.
Important note: When the unit is turned on for the rst time, It should be turned onto high without the
fan on for the rst 4 hours. This will cure the paint, logs, gasket material and the other products used in
the manufacturing process. It is advisable to open a window or door, as the unit will start to smoke and
can irritate some people. After the unit has gone through the rst burn turn the unit off including the
pilot, let the unit get cold then remove the glass door and clean it with a good gas replace glass cleaner,
available at your local ENVIRO dealer.
See Routine MAINTENANCE AND SERVICE on how to remove door to clean glass.
3. A bag of ceramic ber embers and
rock wool embers is provided gently
remove the ember material from the
plastic bag. Spread a layer loosely
across the burner tray. Do not allow any
embers to rest against pilot assembly.
(See diagram provided for proper ember
placement.)
4. DO NOT pack this ember material as
this could create an unsafe condition,
leave embers loose
5. Upon the rst light up, watch for
ignition to ALL burner ports. If a
long delay is noted: First, wait for the
appliance to cool down.
Open the front door of the appliance.
Check to carefully reposition the
embers making sure that burner ports
are not plugged solid or blocked.
Figure 36. Log Placement Step 4.
Figure 37. Ember Placement.
Figure 38. Ascot Burning.