FIREPLACE INSERT INSTALLATION
Approved Venting Method
: Full Chimney Relining
Use a chimney liner system specifically
designed for pellet stove use; follow the
guidelines in the previous section regarding
appropriate liner diameter.
Use the tee supplied by the liner
manufacturer to connect the exhaust outlet
of the stove to the chimney lining system.
Seal the throat of the fireplace with a sheet
metal block-off plate screwed to the walls
of the fireplace.
Seal the top of the chimney opening using
the Top Plate provided by the liner
manufacturer (or, for abnormal installations,
fabricate the top plate from sheet metal).
Use High Temp RTV silicone to seal the top
plate and prevent leaks.
If the liner system is not a “Twist-Lock”
design, all joints should be secured with
three sheet metal screws.
Seal all joints in the liner using High Temp
RTV silicone.
Secure the outside air pipe to the stove using a hose clamp or other mechanical
fastener. The outside air pipe may be run to the top of the chimney system and
terminated (as shown above), or may be run down through the ash dump, in the
case of a masonry fireplace.
Please Note:
Installation diagrams are for reference purposes only and are not drawn to scale, nor
meant to be used as plans for each individual installation. Please follow all venting
system requirements and maintain the required clearances to combustibles.