Page | 36
UnitShutsDownin15‐20
minuteswithan"E‐2"code
oncontrolboard.
1.Loosethermalsensor. 1.Checkbothsidesofthermal
sensorconnection(exhaust
blowerandcontrolboard).
2.Controlboardsettings. 2.StartstoveonminimumHeat
Range5toensureagoodfireis
started.
3.Failuretolightpellets. 3.Checkigniterforbuildupor
failure.
"E‐3"CodeonControlBoard
(Overfire)
1.Convectionblowerfailure 1.Checkconvectionblowerfor
properfunction,replaceif
necessary.
2.Partiallyblockedflue. 2.Checkflueforobstructions.
3.Usingfuelotherthanpremium
woodpellets.
3.UseONLYpremiumwood
pelletsinthisstove.
"E‐4"CodeonControlBoard
(Proofofflamelost)
1.Thehopperisempty. 1.Refillthehopperwithpellets
andrestartthestove.
2.Thehopperlidwasleftopen
toolongduringrefueling.
2.Keepthehopperlidopenfor
theshortestintervalpossible
whenrefueling.Thesafetyswitch
stopstheaugerwhenthehopper
lidisopen.
3.Componentfailure. 3.Anaugermotorfailureor
combustionmotorfailurecan
sometimesresultsinan"E‐4"
code.
4.Blowerspeedissettoohigh,
coolingfireboxtoorapidly.
4.Operatethestovewiththe
blowerspeedandheatrangeat
thesamevalue.
Notes:
1.Wheneverinstructedtocheck/replacethevacuumsensor,alsocheckforlooseorcrackedvacuum
hose.Also,becertainthevacuummeasurementportinthefireboxiskeptclean.
2.Torestartandclearanerrorcodedisplayedonthecon trolboard,push the"ON"buttonandthe
unitshouldresettheerrorandrestart.
3.Ifyouareuncertainaboutthemeaningofanerrorcodeorhaveanyquestionsatall,PLEASE
contacttechnicalsupportat(800)245‐6489