England's Stove Works 25-EPI Stove User Manual


 
Page | 36
UnitShutsDownin1520
minuteswithan"E2"code
oncontrolboard.
1.Loosethermalsensor. 1.Checkbothsidesofthermal
sensorconnection(exhaust
blowerandcontrolboard).

2.Controlboardsettings. 2.StartstoveonminimumHeat
Range5toensureagoodfireis
started.

3.Failuretolightpellets. 3.Checkigniterforbuildupor
failure.
"E3"CodeonControlBoard
(Overfire)
1.Convectionblowerfailure 1.Checkconvectionblowerfor
properfunction,replaceif
necessary.

2.Partiallyblockedflue. 2.Checkflueforobstructions.

3.Usingfuelotherthanpremium
woodpellets.
3.UseONLYpremiumwood
pelletsinthisstove.
"E4"CodeonControlBoard
(Proofofflamelost)
1.Thehopperisempty. 1.Refillthehopperwithpellets
andrestartthestove.

2.Thehopperlidwasleftopen
toolongduringrefueling.
2.Keepthehopperlidopenfor
theshortestintervalpossible
whenrefueling.Thesafetyswitch
stopstheaugerwhenthehopper
lidisopen.

3.Componentfailure. 3.Anaugermotorfailureor
combustionmotorfailurecan
sometimesresultsinan"E4"
code.

4.Blowerspeedissettoohigh,
coolingfireboxtoorapidly.
4.Operatethestovewiththe
blowerspeedandheatrangeat
thesamevalue.
Notes:
 
1.Wheneverinstructedtocheck/replacethevacuumsensor,alsocheckforlooseorcrackedvacuum
hose.Also,becertainthevacuummeasurementportinthefireboxiskeptclean.
 
2.Torestartandclearanerrorcodedisplayedonthecon trolboard,push the"ON"buttonandthe
unitshouldresettheerrorandrestart.
 
3.Ifyouareuncertainaboutthemeaningofanerrorcodeorhaveanyquestionsatall,PLEASE
contacttechnicalsupportat(800)2456489