Check the following items during installation prior to
lighting the multisided burner:
Check all carryover ports for blockage from the ceramic
media
o If there is blockage, use a small pointed tool to
move the ceramic media away from the carryover port.
Check air shutter for correct setting.
o NAT gas – Air shutter 1/8" (3.2 mm) minimum
open
o LP gas – Air shutter full open
For best results when lighting the burner, have your
adjustable ame knob to the HI position, then adjust to
a lower setting after the burner has ignited.
When rst lighting the pilot on the burner, it takes
approximately 60 to 75 seconds to fully heat and energize
the thermopile. Once the thermopile is energized, turn
on the gas valve and light the burner.
AIR SHUTTER
1/8” (3.2mm) OPEN
AIR SHUTTER
FULL OPEN
BURNER INSTRUCTIONS