Before you begin: If you are installing logs onto the VFDR30
model, this burner assembly place is supplied with a set of seven
ceramic fiber logs. Do not handle these logs with your bare hands.
Always wear gloves to prevent skin irritation from ceramic fibers.
After handling logs, wash your hands gently with soap and water
to remove any traces of fiber.
The positioning of logs is critical to safe and clean operation of
this burner assembly. Sooting and other problems may result if the
logs are not properly and firmly positioned on the burner assembly.
Refer to Figure 14 and Figure 15 and corresponding WARNING:
when completing following log placement steps.
1. Place front logs (#1, #2, and #3) between grates and main
burner. Align notches on front logs with locator tabs in base.
2. Place middle log (#4) between front and rear loop of burner.
Note: do not place on top of pilot assembly.
3. Place rear log (#5) on rear log shelf. Bottom flange is to be
placed between the log shelf and burner tube.
4. Place bottom front twig (#6) onto flat areas of middle log (#4)
and bottom end of front twig to the back side of the grate tang
(4th one from the left).
5. Place the rear twig (#7) onto flat area of rear log (#5) and over
the front of the front twig.
Ember Material Placement on Burner
6. After all logs are properly positioned, place small "dime" size
pieces of Rockwool lightly across the front burner tube ports.
Place the ember material (Rockwool pieces) side by side. Do
not stack more than one layer of embers across the burner
ports. No more than (1) one packet of ember material (part
number 15999) evenly placed on the burner, is recommended
on VFDR30 models. See Figure 15.
Figure 15
VFDR30 LOG PLACEMENT (7 LOG SET)
Figure 14
1
2
3
4
6
5
7
EMBER MATERIAL
PLACEMENT
(SHADEDAREAONLY)
Warning: Failure to position the parts in accordance with
this diagram or failure to use only parts specifically approved
with this appliance may result in property damage or personal
injury.
Attention: Do not use Figure 14 or Figure 15 to order logs. Refer
to parts list on page 20 and parts view on page 21 to order logs