Empire Comfort Systems PV-28SV55-(C,G)2H(N,P)-1 Indoor Fireplace User Manual


 
24820-1-0409Page 42
OPTIONAL CONTROLLERS
See your Mantis dealer for correct controller type.
TEMPERATURE CONTROLLERS
FRBTP Battery Operated Remote w/ Programmable Thermostat
FRBTC Battery Operated Remote w/ Thermostat
TRW Battery Operated Wireless Remote Wall Thermostat
TMV2 Thermostat, 2 Stage
T24V Thermostat, 24 Volt
INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION
Installation Instructions for FRBTP, FRBTC, and TRW
Remote Controls FRBTP, FRBTC and TRW are all battery operated devices. Begin installation by unplugging the unit and removing
the front louver panel.
Remove wire nut from black and white wire from junction box.
Black or white wire can be inserted in either remote control receiver connection hole or connected to T24V thermostat screws. There is
no polarity at this connection.
Figure 49
Replace front louver panel and plug unit into outlet. Turn both burner switches to the ON position. Burner switches must remain in the
ON position for remote to function. Set remote from the instructions provided with the remote control. Set T24V thermostat to desired
temperature.
Note: When the heater will not be used for long periods, the burner switches should be in the OFF position, and the heater should be
turned off at the power point.
Installation Instruction for TMV2 - Two Stage Thermostat Model:
Begin installation by unplugging the unit and removing the front louver panel.
Determine mounting location of thermostat. Using standard 18 AWG wire, run four (4) strands of wire into rear of Mantis
(See Figure 50) to junction block. Cut wire to correct length. Remove blue jumper wire from junction block and save for future use.
Connect four (4) new thermostat wires to Mantis using schematic. See Figure 51.
Figure 50
REMOTE
CONTROL
RECEIVER OR
T24V THERMOSTAT
BLACK
BLACK
WHITE
WHITE
RED
JUNCTION
BLOCK
TO
TRANSFORMER
BLUE
TO “T2” (REAR BURNER)
TO “T1” (FRONT BURNER)
WHITE
W1 RW2C
BLUE
TO “T1”
TO “T2”