See the Troubleshooting section at the end of
this document for more information about the
function of this switch.
E2/P SWITCHE2/P SWITCH
E2/P SWITCHE2/P SWITCH
E2/P SWITCH
The E2/P switch is located on the back of the
thermostat body (see fig. 2). This switch
controls how the E2/P terminal of the
thermostat will be energized. When the switch
is in the E2 position (down), the E2/P
terminal will be energized only when in
emergency heat. When the switch is in the P
position (up), the E2/P terminal will always
be energized except when in emergency heat.
Consult the equipment manufacturer or a
qualified heating/cooling service person
before setting this switch. If your system has
no connection to E2/P, no change in the
switch setting is required.
Figure 2. Switch locations on back of thermostat bodyFigure 2. Switch locations on back of thermostat body