Emerson HF956BS Fan User Manual


 
3
Do not install or use fan if any part is
damaged or missing. Call Toll-Free:
1-800-654-3545
WARNING
This product is designed to use only
those parts supplied with this product
and/or any accessories designated
specifically for use with this product by
Emerson Electric Co. Substitution of
parts or accessories not designated for
use with this product by Emerson Electric
Co. could result in personal injury or
property damage.
WARNING
Checking Contents of
Package
Electrical Requirements
1. Unpack the items carefully to avoid
damage to any of the components.
2. Make certain you receive the following
parts:
a.Motor subassembly
b.Blades (3 each)
c. Upper canopy
d.Lower canopy
e.J-hook bag assembly containing:
1. J-hook (2 each)
2. Flat washers (2 each)
3. Lock washers (2 each)
4. Hex nuts (2 each)
f. 24" Hanger pipe assembly
g.8” Hanger pipe(HF948 Only)
h.Bag of parts containing:
1.Wire connectors (3 each)
2.Cable clamps (2 each)
3.M6 x 1/2" Hex head screws
(6 each)
4.M6 Spring washers (6 each)
5.Blade gaskets (3 each)
6.Clevis pin
7.Hairpin clip
8.5/16-18 x 1/4” Setscrews (2 each)
9.Allen wrench
NOTE: Intermixing blades between
fans can cause excessive wobble.
Keep blades in original sets of three.
Fan Assembly
Instructions
1. Put the upper canopy and lower
canopy on the hanger pipe assembly,
facing in the proper direction. (See
Figure 1.)
NOTE: For HF948 Only
. If you are going
to use the 8” pipe, first remove the
hanger assembly from the 22” pipe and
install it on the 8” pipe. Be sure that the
nut is securely tightened and the
hairpin clip properly installed.
2. Pass the motor wires and retention
cable through the hanger pipe
assembly and seat the hanger pipe in
the motor yoke. (See Figure 2.)
HANGER PIPE
ASSEMBLY
LOWER
CANOPY
UPPER
CANOPY
HANGER
ASSEMBLY
Figure 1
Before discarding packaging material,
be certain all parts have been removed.
Your new ceiling fan will require a
grounded electrical supply line of 120 volts
AC, 60 Hz, 15 amp circuit.
The outlet box must be securely anchored
and capable of withstanding a load of at
least 50 pounds.
Turning off wall switch is not sufficient.
To avoid possible electrical shock, be
sure electricity is turned off at the main
fuse box before wiring. All wiring must be
in accordance with National and Local
codes and the ceiling fan must be
properly grounded as a precaution
against possible electrical shock.
WARNING
U.L. Model No.: HF948, HF956
BP7311 48 56" Heat Fans 1/16/08 10:52 AM Page 3