Emerson CF955ORB 00 Fan User Manual


 
9
Trouble Shooting
TROUBLE PROBABLE CAUSE SUGGESTED REMEDY
1. Fan will not start. 1. Fuse or circuit breaker blown. 1. Check main and branch circuit fuses or circuit breakers.
2. Loose power line connections to the fan, or loose 2. Check line wire connections to fan and switch wire
switch wire connections in the switch housing. connections in the switch housing.
WARNING: Make sure main power is turned off.
3. The remote control transmitter battery needs 3. Check that the remote transmitter battery is in good
replacement. condition; the red indicator will illuminate when the key
pad buttons are depressed.
2. Fan sounds noisy. 1. Blades not attached to fan. 1. Attach blades to fan before operating.
2. Screws securing fan blade flanges to motor are 2. Check to make sure the screws which attach the fan
loose. flanges to the motor are tight.
3. Screws holding blades to flanges are loose. 3. Tighten screws securely.
4. Glass bowl loose. 4. Tighten the glass bowl securely.
3. Fan wobbles 1. Setscrew in motor coupling is loose. 1. Raise coupler cover and tighten the setscrew securely.
excessively. 2. Setscrew in hanger ball/downrod assembly is 2. Tighten the setscrew in the hanger ball/downrod assembly.
loose.
3. Screws securing fan blade flanges to motor are 3. Check to be sure screws which attach the fan blade
loose. flanges to the motor are tight.
4. Fan blade flanges not seated properly. 4. Check to be sure the fan blade flanges seat firmly and
uniformly to the surface of the motor. If flanges are
seated incorrectly, loosen the flange screws and retighten
according to the procedure in the section on "How to Put
Your Ceiling Fan Together".
5. Hanger bracket and/or ceiling outlet box is not 5. Tighten the hanger bracket screws to the outlet box,
securely fastened. and/or secure outlet box.
6. Fan blades out of balance. 6. Interchanging an adjacent (side-by-side) blade pair can
redistribute the weight and result in smoother operation.
4. All four lamps will not 1. The remote control transmitter battery needs 1. Replace the 12 V battery; recommended replacement
illuminate. replacement. 12V batteries are Duracell MN21, Eveready A23, and
GP23A.
WARNING: Make sure main power is turned off.
2. The 1.0 amp lamp fuse may have blown and 2. Replace the 1.0 amp fuse with Emerson repair part
and needs replacement. item 19. See page 5 and reverse the lower housing
installation instructions to gain access to the fuse holder.
WARNING: FOR YOUR OWN SAFETY TURN OFF POWER AT FUSE BOX OR CIRCUIT BREAKER
BEFORE TROUBLE SHOOTING YOUR FAN.
!
!
U.L. Model No.: CF955
!