Emerson CF550ORB00 Fan User Manual


 
9
ETL Model No.: CF550
Wall Control Installation (continued)
Wall Control Procedures
SINGLE-POLE INSTALLATION
CAUTION: To reduce the risk of electrical shock,
disconnect the electrical supply circuit before
installing the fan, light kit or receiver.
General
Your Emerson Ceiling Fan/Light Control consists of
wall mounted transmitter and a receiver which is pre-
installed inside the motor assembly. The remote
control is designed to separately control your ceiling
fan speed and light intensity.
Code switches in the transmitter and receiver may be
set in 32 different positions. If your fan and light go on
and off without using your control, you may be getting
interference from other remote units such as garage
door openers, car alarms or security systems. To
remedy this situations, simply change the code switch
combination in your transmitter.
Your wall control has code switches which must be
set in one of 32 possible code combinations (Figure
15). The five levers (numbered 1, 2, 3, 4, and 5) on
the switches are factory-set in the ON (up) position.
Change the switch settings as follows:
1. Slide the five switch levers in the wall control to
your choice of ON (up) or down positions. Use a
ball-point pen or small screwdriver and slide the
levers firmly up or down.
2. The sixth switch marked ON and I is for dimming
control of lights: Set switch to ON to allow for
dimming of the lights. Set switch to I for no
dimming of the lights such as for fluorescent bulbs.
WALL CONTROL
CODE SWITCHES
ON
1
23
4
5I
CODE
SWITCHES
WALL
CONTROL
Figure 15
EMERSON
®
HI
MED
LOW
FAN OFF
LIGHT
ONOFF
FAN/LIGHT
WALL CONTROL
HOT BLK
NEUTRAL
BLACK
GROUND
LOAD
BLACK
RECEIVER LOCATED
ON TOP OF THE
CEILING FAN
Turning off wall switch is not sufficient. To avoid
possible electrical shock, be sure electricity is
turned off at the main fuse or circuit breaker box
before wiring. All wiring must be in accordance with
National and Local codes and the ceiling fan must be
properly grounded as a precaution against possible
electrical shock.
WARNING
!
Figure 16
Preset Memory Feature
Your Emerson receiver is equipped with a preset
memory feature. If the AC supply to the receiver is
powered through a wall switch, when the switch is
turned OFF, the control will remember the light
intensity and fan speed. When the switch is turned
back ON the light and fan will resume operation as
they were prior to the switch being turned OFF.
Setting Operating Frequency of Wall Control