Emerson CF550ORB00 Fan User Manual


 
WARNING: To avoid fire, shock, and serious personal injury, follow these instructions.
Safety Instructions
1. Read your owner’s manual carefully and keep it for future reference.
2. Before servicing or cleaning unit, switch power off at service panel and lock service panel
disconnecting means to prevent power from being switched on accidentally. When the service
disconnecting means cannot be locked, securely fasten a warning device, such as a tag, to the
service panel.
3. Be careful of the fan and blades when cleaning, painting, or working near the fan. Always turn off
the power to the ceiling fan before servicing.
4. Do not put anything into the fan blades while they are turning.
5. Do not operate reversing switch until fan blades have come to a complete stop.
Additional Safety Instructions for Installation
1. To avoid possible shock, be sure electricity is turned off at the fuse box before wiring, and do not
operate fan without blades.
2. All wiring must be in accordance with the National Electrical Codes “ANSI/NFPA 70-2011” and Local
Electrical Codes. Use the National Electrical Code if Local Codes do not exist. The ceiling fan must
be grounded as a precaution against possible electrical shock. Electrical installation should be
made or approved by a licensed electrician.
3. The outlet box and joist must be securely mounted and capable of reliably supporting at least
50 pounds. Use only U.L. outlet boxes listed as “Acceptable for Fan Support of 22.7 kg. (50 lbs.) or
less”, and use the mounting screws provided with the outlet box. Most outlet boxes commonly used
for support of light fixtures are not acceptable for fan support and may need to be replaced. Consult
a qualified electrician if in doubt.
4. The downrod furnished with the fan provides the minimum recommended floor to fan blade
clearance for an 8 foot ceiling.
5. The fan must be mounted with the fan blades at least 7 feet from the floor to prevent accidental
contact with the fan blades.
6. Follow the recommended instructions for the proper method of wiring your ceiling fan. If you do not
know enough about electrical wiring, have your fan installed by a licensed electrician.
NOTE: All setscrews must be checked and re-tightened where necessary before installation.
NOTE: This fan is suitable for use with solid-state speed controls.
WARNING: To reduce the risk of fire or electric shock, this fan should only be used with fan speed
control, Model No. FR-7861LM-06 manufactured by Rhine Electric Co., Ltd.
WARNING: To avoid fire, shock or injury, do not use an Emerson or any other brand of control not
specifically approved for this fan.
WARNING: This product is designed to use only those parts supplied with this product and/or any
accessories designated specifically for use with this product by Emerson Electric Co. Substitution of
parts or accessories not designated for use with this product by Emerson Electric Co. could result in
personal injury or property damage.
WARNING: To reduce the risk of personal injury, do not bend the blade flange when installing the
blade flanges, balancing the blades or cleaning the fan. Do not insert foreign objects in between
rotating fan blades.
WARNING: To reduce the risk of electrical shock, this fan must be installed with an isolating wall
control/switch.
2
ETL Model No.: CF550
!
WARNING
This Manual Is Designed to Make it as Easy as Possible for You to Assemble,
Install, Operate and Maintain Your Ceiling Fan
Tools Needed for Assembly
One Phillips head screwdriver One stepladder
One 1/4” blade screwdriver One wire stripper
MATERIALS
Wiring outlet box and box connectors must be of
type required by the local code. The minimum wire
would be a 3-conductor (2-wire with ground) of the
following size:
Installed Wire Length Wire Size A.W.G.
Up to 50 ft. 14
50-100 ft. 12
Before assembly your ceiling fan, refer to section
on proper method of wiring your fan (page 7).
If you feel you do not have enough wiring
knowledge or experience, have your fan installed
by a licensed electrician.
WARNING
!