Emerson CF2455ORB00 Fan User Manual


 
9
1-1/4"
THREADED
STUDS (2)
HANGER
BRACKET
OUTLET BOX
RECEIVER
CEILING
COVER
Figure 16
BLUE RECEIVER WIRE
YELLOW RECEIVER WIRE
BLUE FAN WIRE
DOWNROD
BLACK FAN WIRE
SW105 RECEIVER
WHITE FAN WIRE
WHITE RECEIVER WIRE
BLACK RECEIVER WIRE
YELLOW FAN WIRE
BLACK/WHITE RECEIVER WIRE
BLACK
SUPPLY
WIRE
WHITE
SUPPLY
WIRE
Check to see that all connections are tight, including
ground, and that no bare wire is visible at the wire
connectors, except for the ground wire. Do not
operate fan until blades are in place. Noise and fan
damage could result.
WARNING
!
4. After connections have been made, separate the
white and green wires from the black, blue and
yellow wires.
5. Carefully turn the wires upward and insert them up
through the open side of the hanger bracket and
into the outlet box. Push the green and white wires
into one side of the outlet box; push the black, blue
and yellow wires into the other side of the outlet
box.
Figure 15
Final Assembly
1. Screw the two 1-1/4” threaded studs (supplied) into
the tapped holes in the hanger bracket (Figure 16).
2. Lift the ceiling cover up to the threaded studs and
turn until studs protrude through the holes in the
ceiling cover (Figure 17).
3. Secure the ceiling cover in place by installing two
lockwashers and two knurled knobs (supplied)
(Figure 17). Tighten the knurled knobs securely
until the ceiling cover fits snugly against the ceiling
and the hole in the ceiling cover is clear of the
downrod.
4. Screw in three 40-watt (maximum) candelabra
base lamps in the uplight assembly sockets and
three 60-watt (maximum) candelabra base lamps in
the light kit plate sockets for the lower light.
1-1/4"
THREADED
STUD
CEILING COVER
KNURLED KNOB
LOCKWASHER
Figure 17
To avoid possible fire or shock, make sure that the
electrical wires are completely inside the outlet box
and not pinched between the ceiling cover and the
ceiling.
WARNING
!