PROGRAMMING
Energy Saving Factory Pre-Program
The 1F97-1277 thermostats are programmed with the energy saving settings shown in the table below for all days of the week.
If this program suits your needs, simply set the thermostat clock and press the RUN button.
The table below shows the factory set heating and cooling schedule for all days of the week.
* You can eliminate these two program periods in the conguration menu (reference #4) if the building is occupied all day.
Day will change to 6:00 am and can be programmed as required.
Planning Your Program – Important
The Heating and Cooling Program schedules below allow you to pencil in your own program times and temperatures.
The 1F97-1277 comes congured for 7 day programming and can also be congured for 5+1+1 programming
(see conguration section).
Factory settings are listed on Monday, Saturday and Sunday. If you are re-programming a 5+1+1 day schedule,
pencil in your own times and temperatures directly below the factory times and temperatures.
If you are re-programming a 7 day ll in all lines with the times and temperatures you want.
Keep the following guidelines in mind when planning your program.
• In Heating, lower temperatures will save energy.
• In Cooling, higher temperatures will save energy.
If you plan on using Auto Changeover, do not program the heating higher than the cooling.
Worksheet for Re-Programming 5+1+1 and 7 Day Program
*Wake Up
(Morning)
Leave For Work
(Day)
*Return Home
(Evening)
Go To Bed
(Night)
Heating
Program
6:00 AM 70°F 8:00 AM 62°F 5:00 PM 70°F 10:00 PM 62°F
Cooling
Program
6:00 AM 78°F 8:00 AM 85°F 5:00 PM 78°F 10:00 PM 82°F
Cooling
Program
Wake Up Leave For Work Return Home Go To Bed
(Morning) Fan (Day) Fan (Evening) Fan (Night) Fan
MON
6:00 AM 78°F Auto 8:00 AM 85°F Auto 5:00 PM 78°F Auto 10:00 PM 82°F Auto
TUE
WED
THU
FRI
SAT
6:00 AM 78°F Auto 8:00 AM 85°F Auto 5:00 PM 78°F Auto 10:00 PM 82°F Auto
SUN
6:00 AM 78°F Auto 8:00 AM 85°F Auto 5:00 PM 78°F Auto 10:00 PM 82°F Auto
Heating
Program
Wake Up Leave For Work Return Home Go To Bed
(Morning) Fan (Day) Fan (Evening) Fan (Night) Fan
MON
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
TUE
WED
THU
FRI
SAT
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto
SUN
6:00 AM 70°F Auto 8:00 AM 62°F Auto 5:00 PM 70°F Auto 10:00 PM 62°F Auto