Electrolux LU4 9QQ Air Conditioner User Manual


 
electrolux EXP09CS1WI front/rear view 11 electrolux EXP09CS1WI installation of window kit 11
Installation in a sliding sash window
1. Connect the rain guards to the insect guard net
Insert all three projections on each rain guard into the
holes in the insect guard net.
Side “A” will now be uppermost, as indicated in the
diagram.
. Attach the guard combined with insect guard net to the
window panel
Push the insect guard net rmly to ensure that its four
projections t into the holes in the window panel.
Side “A” will now be at the top, as indicated in the
diagram, when it is installed in the window.
3. Cut the foam seal A (adhesive type) to the proper length
and attach it to the window frame
4. Install the window panel into the window frame
(A) If the inner height of the window is between 559mm and
609mm inclusive:
The window panel cannot be installed in windows less
than 559mm high, as you will be unable to shut the
exhaust cover.
In such cases the exhaust cover will have to be removed
prior to installing the window panel.
Remove the adjustment panel from the window panel,
and cut the window panel to the same height as the
window.
Open the window sash and place the window panel
on the window frame.
Secure the window panel to the window frame with 
screws.
Insect guard net
Hole
Projection
Rain guard
“A”
“A”
Projection
Window
panel
Window
panel
Window
panel
Exhaust cover
Cut
559mm - 609mm
Adjustment panel
Foam seal A
(adhesive type)