Electrolux EAS(C,E)12P5ASK(W,S,M) Air Conditioner User Manual


 
1. The inside and outside connecting
cable can be connected without
removing the front grille.
2. Connecting cable between indoor unit
and outdoor unit shall be approved
polychloroprene sheathed flexible cord,
type designation H07RN-F or heavier
cord.
3. Lift the indoor unit panel up, remove
the electrical box cover by loosening
the screw.
4. Ensure the colour of wires of outdoor
unit and the terminal Nos. are the same
to the indoors respectively.
5. Wrap those cables not connected with
terminals with insulation tapes, so that
they will not touch any electrical
components. Secure the cable onto the
control board with the cord clamp.
Connect the cable to the indoor unit
Electrical box
cover
21 electrolux electrical work
electrical work electrolux 22
40mm
40mm
10mm
10mm
< 18000 btu's (Cool model)CABLE
> 18000 btu's (Heat & Cool model)CABLE
Cable code
< 18000 btu's (Heat & Cool model)CABLE
40mm
10mm
40mm
10mm
"Cable A"
"Cable C”
"Cable B"
or
Cable code
Cable code
Cable code
< 24000
COOL MODELS
Btu's
MODELS
24000 Btu's
< 24000 Btu's
HEAT AND COOL MODELS
1 2(N) 3 4
1 2(N) 3 4
1 2(N) 3 4 1 2(N)
or
or
Wire connector of indoor unit
Wire connector of indoor unit
Wire connector of indoor unit
or
or
"Connector A"
"Connector A”
"Connector A"
"Connector B"
"Connector B"
Cables
board
Cables
board
Cables
board
Cables
board
Cables
board