EarthStone BV400C-2 Indoor Fireplace User Manual


 
INSTALLATION
PAGE 7
FIREPLACE INSTALLATION
BV400C-2 MINIMUM FIREPLACE DIMENSIONS
Approximate minimum dimensions into fireplace:
Height: 20”
Width: (front-29 ¾”), (rear-21 ½”)
Depth: 15 ¾
CATALYTIC TEMPERATURE PROBE
Install temperature probe prior to installing insert.
To install the Catalytic Temperature Probe locate the plug on the
top, right-hand side of the bypass control rod. Remove the plug,
install the sleeve, and place probe in sleeve. It may be necessary
to bend the flange on the plug so it won't interfere with the probe
temperature indicator.
The Catalytic Temperature Probe is provided so you can monitor
the temperature of your Catalytic Combustor. Once you have es-
tablished a fire and the Catalytic Temperature Probe indicates the
temperature of your Catalytic Combustor is between 500° - 600° F
(approximately 20 - 25 minutes) close the Bypass Damper Con-
trol. Depending on the type and size of the fuel load as well as the
length of time the stove has been burning, your Catalytic Combus-
tor should operate between 1000 - 1800° F.
POWER CORD CHANGEOVER
DANGER: Risk of electrical shock. Disconnect power be-
fore servicing unit. Do not route power cord beneath
heater.
To change the power cord from one side of insert to the other,
perform the following steps:
1. Ensure power cord in NOT
plugged in.
2. Remove the louver blower panels on each side of fuel door as
follows. Each panel is held in place by two ¼” head screws.
Using a ¼” socket or nut driver, remove the screws
3. Remove panels by pulling them outward slightly then forward.
4. Locate terminal block on right side of unit. Write down the lo-
cations where the black, white and green leads from the
power cord are attached to the terminal block. Disconnect
these three wires then reinstall them onto the terminal block
on the left side of unit in the same corresponding positions (as
you had written down).
5. Reinstall panels.
CHIMNEY
TERMINATION CAP
ENSURE CHIMNEY
IS SOUND
MASONRY FIREPLACE:
APPROVED LINER –
6” DIA. FLEX OR
RIGID 24/26 MSG BLACK
OR BLUED STEEL PIPE
OR 2100° HT LINER
FACTORY BUILT (ZC)
FIREPLACE –
APPROVED LINER – 6”
DIAMETER 2100° HT
LINER
REMOVE FIRE-
PLACE DAMPER
OR SECURE
OPEN