DSCover Satellite Products PC1555MX Home Security System User Manual


 
43
Table2: Contact ID Zone Alarm/Restoral Event
Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using
the standard (non-automatic) Contact ID reporting format.
Table 3: SIA Format Automatic Zone
Alarm/Restoral Codes
Section # Reporting Code Code Sent When...
Dialer
Direction*
Automatic
Contact ID
Codes
SIA Auto Rep
Codes**
[349-350] AC Line Trouble/Rest. AC power to control panel is disconnected or inter-
rupted/AC power restored (Both codes follow AC Fail-
ure Comm. Delay.)
MA/R (3) A1 AT-00/AR-00
[349-350] Main Bell Trouble/Rest. open circuit detected across bell terminals/bell circuit
closed
MA/R (3) 21 UT-99/UJ-99
[349-350] Fire Trouble/Rest. a trouble occurs/restores on a fire zone MA/R (3) 73 FT-00/FJ-00
[349-350] Auxiliary Power Trouble/
Rest.
aux voltage supply trouble/restoral MA/R (3) AA YP-00/YQ-00
[349] TLM Failure telephone line monitoring trouble (sent via LINKS. Do
not program if LINKS not used)
MA/R (3) 51 LT-00
[350] TLM Restore Telephone line trouble restore MA/R (3) 51 LR-00
[349-350] Gen System Trouble/Rest. “Service Required” trouble occurs (view troubles using
[*][2])/trouble restored
MA/R (3) 33 ET-00/ER-00
[349-350] Gen System Supervisory
Trouble/Rest.
control panel loses/restores communications with mod-
ule(s) connected to the Keybus
MA/R (3) 33 ET-00/ER-00
[351] Line 1 or 2 FTC Restoral control panel has restored communications to central
station on line 1 or 2 (after FTC)
MA/R (3) 54 YK-00
[351] Event Buffer is 75% Full event buffer is almost full since last upload MA/R (6) 23 JL-00
[351] DLS Lead In downloading session start MA/R (4) 11 RB-00
[351] DLS Lead Out downloading session complete MA/R (4) 12 RS-00
[351] Zone Fault/Rest. one or more zones have faults/restored MA/R (3) 72 UT-00/UJ-00
[351] Delinquency programmed amount of time (days or hours) for delin-
quency has expired without zone activity or without sys-
tem being armed
MA/R (4) 54*** CD-00
[352] Periodic Test periodic system test transmission T (6) A2 RP-00
[352] System Test [*][6] bell/communications test T (6) A1 RX-00
[352] LINKS Test LINKS test transmission T (6) A3 TX-00
[353] Wireless Device Low Bat-
tery Trouble/Rest.
wireless zones (WLS904, WLS905, WLS907); panic
pendants (WLS908); handheld keypads (WLS910);
wireless keys (WLS909) have low battery/all low batter-
ies restored
MA/R (3) 84 XT-00/XR-00
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
** UU = user number (user01-42); ZZ = zone number (01-32)
***Program the “Fail to close” event code [(4)54] to report either closing or activity delinquency.
Make sure your central station is aware of the application of this reporting code.
Medical Alarms (1)34 Entry / Exit
(1)AA Medical (1)35 Day / Night
(1)A1 Pendant Transmitter (1)36 Outdoor
(1)A2 Fail to Report In (1)37 Tamper
Fire Alarms (1)38 Near Alarm
(1)1A Fire Alarm General Alarms
(1)11 Smoke (1)4A General Alarm
(1)12 Combustion (1)43 Exp. module failure
(1)13 Water Flow (1)44 Sensor tamper
(1)14 Heat (1)45 Module Tamper
(1)15 Pull Station
(1)4A Cross Zone Police Code
(1)16 Duct 24 Hour Non-Burglary
(1)17 Flame (1)5A 24 Hour non-Burg
(1)18 Near Alarm (1)51 Gas detected
Panic Alarms (1)52 Refrigeration
(1)2A Panic (1)53 Loss of Heat
(1)21 Duress (1)54 Water Leakage
(1)22 Silent (1)55 Foil Break
(1)23 Audible (1)56 Day Trouble
Burglar Alarms (1)57 Low bottled Gas level
(1)3A Burglary (1)58 High Temp
(1)31 Perimeter (1)59 Low Temp
(1)32 Interior (1)61 Loss of Air Flow
(1)33 24 Hour
Zone Definition
SIA Auto Rep
Codes*
Zone Alm/Rest.
Delay, Instant, Interior, Delay
Stay/Away, Interior Stay/Away,
24Hr Burg.
BA-ZZ/BH-ZZ
Standard 24Hr Fire, Delayed
24Hr Fire
FA-ZZ/FH-ZZ
24Hr Supervisory US-ZZ/UR-ZZ
24Hr Supervisory Buzzer UA-ZZ/UH-ZZ
24Hr Sprinkler SA-ZZ/SH-ZZ
24Hr Gas GA-ZZ/GH-ZZ
24Hr Heat KA-ZZ/KH-ZZ
24Hr Medical MA-ZZ/MH-ZZ
24Hr Emergency (non-medical) QA-ZZ/QH-ZZ
24Hr Waterflow WA-ZZ/WH-ZZ
24Hr Freeze ZA-ZZ/ZH-ZZ
24Hr Holdup HA-ZZ/HH-ZZ
24Hr Panic PA-ZZ/PH-ZZ
Latching 24Hr BA-ZZ/BH-ZZ
* ZZ = zones 01-32
WWW.DIYALARMFORUM.COM