DSCover Satellite Products PC1555MX Home Security System User Manual


 
Programming Worksheets
39
[365] Opening/Closing Communicator Call Directions
(Section 5.5 “Communicator – Dialing” on page 17)
Default Option ON OFF
ON I________I
1 1st Telephone Number Disabled
OFF
I________I
2 2nd Telephone Number Disabled
OFF
I________I
3 1st Telephone Number (via LINKS) Disabled
OFF
I________I
4 2nd Telephone Number (via LINKS) Disabled
OFF
I________I
5-8 For future use
[367] System Maintenance Alarm/Restore Communicator Call Directions
(Section 5.5 “Communicator – Dialing” on page 17)
Default Option ON OFF
ON I________I
1 1st Telephone Number Disabled
OFF
I________I
2 2nd Telephone Number Disabled
OFF
I________I
3 1st Telephone Number (via LINKS) Disabled
OFF
I________I
4 2nd Telephone Number (via LINKS) Disabled
OFF
I________I
5-8 For future use
[368] System Test Transmissions Communicator Call Directions
(Section 5.5 “Communicator – Dialing” on page 17)
Default Option ON OFF
ON I________I
1 1st Telephone Number Disabled
OFF
I________I
2 2nd Telephone Number Disabled
OFF
I________I
3 1st Telephone Number (via LINKS) Disabled
OFF
I________I
4 2nd Telephone Number (via LINKS) Disabled
OFF
I________I
5-8 For future use
NOTE: The LINKS1000 backup call directions will only back up their respective telephone numbers.
[370] Communication Variables
Default Section Page #
003 I_______I_______I_______I
Swinger Shutdown (Alarms and Rest) (001-014 Transmissions, 000=disabled) 5.19 24
003
I_______I_______I_______I
Swinger Shutdown (Tampers and Rest)(001-014 Transmissions, 000=disabled) 5.19 24
003
I_______I_______I_______I
Swinger Shutdown (Maint and Rest) (001-014 Transmissions, 000=disabled) 5.19 24
000
I_______I_______I_______I
Transmission Delay (001-255 seconds) 5.15 23
030
I_______I_______I_______I
AC Failure Communication Delay (001-255 minutes) 5.8 17
003
I_______I_______I_______I
TLM Trouble Delay (No. of checks required - valid entries 003 - 255) 5.12 22
030
I_______I_______I_______I
Test Transmission Cycle (land line) (001-255 days) 5.14 23
030
I_______I_______I_______I
Test Transmission Cycle (LINKS) (001-255 days) 5.14 23
007
I_______I_______I_______I
Zone Low Battery Transmission Delay (000-255 days) 5.8 17
030
I_______I_______I_______I
Delinquency Transmission Cycle (000-255 days/hours) 5.8 17
NOTE: To disable the AC failure communications delay, program [000].
[371] Test Transmission Time of Day
(Section 5.14 “Test Transmission” on page 23)
Default
9999 I_______I_______I_______I_______I
(Valid entries are 0000-2359, 9999 to disable)
[380] First Communicator Option Code
Default Option ON OFF Section Page #
ON I_______I
1 Communications Enabled Communications Disabled 5.5 17
OFF I_______I
2 Restorals on Bell Time-out Restorals Follow Zones 5.8 17
OFF I_______I
3 Pulse Dialing DTMF Dialing 5.5 17
ON I_______I
4 Switch to Pulse Dialing on 5th Attempt DTMF Dial For All Attempts 5.5 17
OFF I_______I
5 3rd Telephone Number enabled 3rd Telephone Number disabled 5.7 17
OFF I_______I
6 Alternate Dial (1st and 3rd) Call 1st Number, Backup to 3rd 5.7 17
OFF I_______I
7 Call LINKS as well as Land Line LINKS is Backup of Land Line(s) 5.26 25
OFF I_______I
8 Delinquency Follows Zone Activity (Hours) Delinquency Follows Arming (Days) 5.8 17
WWW.DIYALARMFORUM.COM