Drolet SIT 0.820.633 Stove User Manual


 
ULTRA FLAME DIRECT VENT GAS STOVE 10
13. Seal around the 8 in. pipe to prevent cold air to get into
the house.
14. Seal around the cover slots to avoid water infiltration
into the vent terminal;
15. Insert spring spacers into the 5 in. flexible pipe;
16. Put some high temp silicone on the stove’s 5 in.
flange. Insert one locking band on the 5 in. pipe and
insert it on the stove flange. Make sure seal is perfect.
Tight the locking band
17. Fix the 8 in. pipe to the stove with three metal screws.
18. Fix Seal around the 8 in. pipe to prevent cold air to
get into the house. your stove to the floor ;
19. Installation is now complete.
5" LOCKING BAND
SCREWS
5" FLEXIBLE FLUE PIPE
8"RIGID
A
Direct Vent Kit for Corner Installation
VENT TERMINAL
45 ELBOW
O
60" MAX
RADIATION SHIE
L
VENT PIPES
Corner Installation
1. Move the stove to its position;
2. Install temporary a 8 in. section (4) to visualize where
the opening to be done thru the wall. Center of the
opening should be at about 23 ½ “above the base of
the stove;
Note: Horizontal run should have a slope of ¼ in per foot.
Corner Installation Details
3. Make a 10-1/2" x 10-1/2" opening in the wall, 23-1/2"
inches in order to introduce the radiation shield thru
the wall;
4. Cut the radiation shield to length if necessary and
install as shown. Secure with four #10 1” wood screws;
5. Install the vent terminal (13) with 2 ½ screws (12). You
may want to remove the vent casing for easy access
and manipulation, Keep only in place the wall plate;
6. Insert the 8 in. pipe into the round opening of the
interior black wall plate (7). Fix the insulation pad (9)
around the 8 in. pipe with the aluminum tape;
7. Keeping the insulation joint of the 8 in. pipe down,
insert it into the vent terminal wall plate;
CUT TO LENGTH
10-1/2" X 10-1/2"
OPENING