ELATION Fireplace Insert 14
BURNER REMOVAL AND INSTALLATION
REMOVAL:
• Remove the glass front assembly as shown on page
13.
• Remove the logs.
• Unscrew the line leading to the main orifice under burner (below floor of firebox)
and then unscrew the orifice fitting from the burner.
• Lift out burner.
WARNING: NEVER OPERATE THE FIREPLACE INSERT WITHOUT HAVING THE
ORIFICE PROPERLY SCREWED TO THE VENTURI TUBE. THIS COULD RESULT IN
SERIOUS DAMAGE TO THE GAS INSERT AND IS A SERIOUS RISK OF FIRE .
NOTE: For an optimal performance the air shutter opening should be 1/8” opening for natural
gas and 1/4” to 5/16” for propane.