Drolet Nova 820 Indoor Fireplace User Manual


 
ELATION Fireplace Insert 12
If you wish to make a direct electrical connection to the blower without using the six-foot
cord supplied, route a 120 volt, 60 Hz electrical power supply line to the same location.
Remove the power cord and connect the 120V line as per the following procedure :
Unscrew the speed control unit and pull a few inches away from the junction box
Unscrew the two marr connectors attached to the cord (P) and the cord ground
Remove the cord and route the supply line through the same holes
Make the electrical connection with the same wires the cord was attached to
Screw the ground wire to the junction box (G)
Screw the speed control unit back in place
P
P
G
CONNECT THE POWER LINE TO THE SAME
WIRES THE CORD WAS CONNECTED TO (P)
SPEED CONTROL
JUNCTION BOX
If you prefer to use the six-foot cord supplied, just connect it to a 120V outlet.
Move the ELATION to the desired position and shim the unit to a level position.
Connect gas line to the insert at the right side using listed connectors
Check the gas line piping for leaks. Use a soap and water solution.
WARNING: DO NOT USE OPEN FLAME TO CHECK LEAKS.