Drolet Nova 820 Indoor Fireplace User Manual


 
ELATION Fireplace Insert 10
INSTALLATION
SAFETY NOTICE
Improper installation may result in a house fire. Follow installation directions. Installation must
be in accordance with local building codes or, in the absence of local codes, with current
CAN/CGA B 149 installation codes for gas appliances in Canada and current National Fuel Gas
Code ANSI Z223.1 in the USA.
INSTALLATION SHOULD BE DONE BY A QUALIFIED INSTALLER.
THIS FIREPLACE INSERT MUST BE VENTED OUTSIDE.
THIS FIREPLACE INSERT MUST BE ELECTRICALLY GROUNDED IN ACCORDANCE
WITH LOCAL CODES OR, IN THE ABSENCE OF LOCAL CODES, WITH THE National
Electrical Code, ANSI/FPA 70, or the CANADIAN ELECTRICAL CODE, CSA C22.1.
POSITIONING THE INSERT
The ELATION may be installed as an insert into an existing masonry fireplace OR as an insert
into an existing listed solid fuel burning factory built fireplace.
Provide adequate accessibility clearances for servicing and proper operation.
Provide adequate clearances around air openings into the combustion chamber..
This appliance has a built-in draft hood, so no additional external draft hood is required.
If installing in a factory built fireplace, you may remove the damper, glass doors, screen,
screen holder, baffles, and smoke shelf provided that what you take out can be reinstalled.
Also you
must retain the pieces you have removed, in case someone would like to use the
listed solid fuel burning factory built fireplace at a later date.
A GAS APPLIANCE MUST NOT BE CONNECTED TO A CHIMNEY FLUE SERVING
A SEPARATE SOLID-FUEL BURNING APPLIANCE.