Drolet ECO-35 Stove User Manual


 
6
STOVE INSTALLATION
3"
SIDE WALL
6"
2" *
BACK WALL
Figure 1
Back wall installation
ADJACENT WALL
2"
ADJACENT WALL
2"
3"
3"
Figure 2
Corner installation
ECO-35 FREESTANDING PELLET STOVE
Width: 22 1/4”
Height: 28 1/2”
Depth: 25 3/16”
Weight: 190 lbs.
Flue size: 3” or 4”
Hopper Capacity: Up to 35 lbs.
(This can vary slightly depending on pellet size, length, and diameter)
EPA status: exempt
Burn rate: 1.3 lbs to 4.1 lbs per hour
BTU range: 8,200 to 35000
Electrical consumption: 3.5 Amps lighting cycle
2.5 Amps. continuous duty
Control board fuses: Main: 7.5A-250V fastblow
Igniter: 5A-250V fastblow
Electrical requirement: 120VAC 15A
Approved installations: mobile home, conventional
PREPARATION
Factory packaging must be removed, and some minor assembly work is
required prior to installation :
The black knobs must be attached to heat exchanger rods
The coil handle must be attached to handle rod
CLEARANCES
The ECO-35 has been tested and listed for installation in regular and
mobile homes.(refer figure 1 & 2)
FLOOR PROTECTION: minimum 6” in the front and 6” on each side. The
stove must be placed on a continuous (grouted joints) non-combustible
material such as ceramic tile, cement board, brick, 3/8” millboard or
equivalent, or other approved or listed material suited for floor protection.
NOTE: ceramic tile, or any tile, requires a continuous sheet beneath to
prevent the possibility of embers falling through to the combustible floor if
cracks or separation should occur in the finished surface, this would
include floor protection for Built-in raised hearths. Check local codes for
approved alternatives.
Clearances are measured from the sides, back and face (door opening) or
stove body (refer to fig. 3).
DO NOT USE MAKESHIFT MATERIALS OR COMPROMISES IN THE
INSTALLATION OF THIS UNIT.
INSTALL VENT WITH CLEARANCES SPECIFIED BY THE VENT
MANUFACTURER.
This heating unit must serve as a supplementary heat source. An alternative heat source
should be available in the home if needed. The manufacturer cannot be responsible for
additional heating costs associated with the use of an alternative heat source.
It is highly recommended that the user buys this product from a retailer who can provide
installation and maintenance advices.
6"
6"
6"
Figure 3
Floor protection