12
HFPI9280, DFPI2311
If the unit was operating prior to servicing allow at least 10 minutes for light bulbs and
heating element to cool off to avoid accidental burning of skin.
Disconnect power before attempting any maintenance or cleaning to reduce the risk of
electric shock or damage to persons.
TO REPLACE POWER CORD
1. Remove the glass doors and trim from the unit and remove it from the opening.
2. Unscrew the screws located in the middle of the top and the two screws at the back of
the top.
3. Remove the top being careful not to damage any of the attached wiring.
4. Remove the screws from top left hand and right hand sides.
5. Remove the screws from the middle of the back panel.
6. Gently lift the inner panel up just enough to gain access to the front glass.
7. Locate and remove the front glass by pulling it out of the slots being careful not to
bump or drop it.
8. With needle nose pliers grasp the power cord strain relief grommet from inside the
cover and push while twisting to remove.
9. Remove the power cord wiring connections from the circuit board being careful not to
damage the terminal connections.
10. Install the new power cord through the hole in the cover and connect all of the wiring
connections in their original locations.
11. Install the power cord retaining grommet on the power cord and insert into the hole
in the cover.
12. Reassemble in the reverse order as above.