Dimplex DFG3033 Indoor Fireplace User Manual


 
9
Fireplace Installation
Option #3
Wire a dedicated, properly

15 Amp rating. Allow up to eight
(8) feet (2.4 m) of service cable
for connecting power supply to


CAUTION: 

cable with ground wire (three
(3) wires total) for the incoming


to meet local and national
electrical codes for rated
power consumption.
Remove the outer jacket and
strip the individual conductor from
the end.
Loosen the screw securing
the junction box cover and
remove the cover.
Take the cables out from the
junction box, loosen the two wire
twist nuts and remove the cord
set (Figure 2).
Route the power supply wire
through the knockout on supplied
alternative junction box cover
and secure with a wire clamp (not
supplied) (Figure 3).
Connect the black wire (live)
from the unit to the black wire
from power supply (Figure 3).
Figure 2
Figure 3