Desa VF-18P-PDG,VF-24N-PDG, VF-24P-PDG, VF-18NPDG, VF-24N-BTB, VF-18N-BTB, VF-24P-BTB, VF-18P-BTB Indoor Fireplace User Manual


 
111826-02F
For more information, visit www.desatech.com
16
TROUBLESHOOTING
Continued
WARNING: If you smell gas
• Shut off gas supply.
• Do not try to light any ap pli ance.
• Do not touch any elec tri cal switch; do not use any phone in your
build ing.
• Immediately call your gas sup plier from a neighbor’s phone. Follow
the gas sup pli er’s in struc tions.
• If you cannot reach your gas sup plier, call the fi re de part ment.
IMPORTANT: Operating appliance where impurities in air exist may create odors. Cleaning
supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles,
etc., create fumes. These fumes may mix with combustion air and create odors. These
odors will disappear over time.
POSSIBLE CAUSE
1. Battery is not installed. Battery power is
low
1. Metal expanding while heating or con-
tract ing while cooling
1. Appliance burning vapors from paint,
hair spray, glues, cleaners, chem i cals,
new carpet, etc. (See IM POR TANT
state ment above)
2. Low fuel supply (propane/LP only)
3. Gas leak. See Warn ing statement at
top of page
1. Not enough fresh air is available
2. Low line pressure
3. ODS/pilot is partially clogged
1. Gas leak. See Warn ing statement at
top of page
2. Control valve or gas control defective
1. Foreign matter be tween con trol valve and
burner
2. Gas leak. See Warn ing statement at
top of page
REMEDY
1. Replace 9-volt batteries in receiver and
remote control
1. This is common with most appliances. If
noise is excessive, contact quali fi ed ser vice
per son
1. Open window to ventilate room. Stop us ing
odor causing prod ucts while appliance is
running
2. Refi ll supply tank (propane/LP only)
3. Locate and correct all leaks (see Check ing
Gas Con nec tions, page 9)
1. Open window and/or door for ven ti la tion
2. Contact local natural or pro pane/LP gas
company
3. Clean ODS/pilot (see Cleaning and Main-
te nance, page 13)
1. Locate and correct all leaks (see Check ing
Gas Con nec tions, page 9)
2. Replace control valve or gas control
1. Take apart gas tubing and remove for eign
mat ter
2. Locate and correct all leaks (see Check ing
Gas Con nec tions, page 9)
OBSERVED PROBLEM
Remote does not function (Remote-Ready
Models Only)
Appliance produces a click ing/tick ing noise
just after burners are lit or shut off
Appliance produces un wanted odors
Appliance shuts off in use (ODS operates)
Gas odor even when control knob is in OFF
position
Gas odor during combustion
TROUBLESHOOTING