Desa (V)T32EN Indoor Fireplace User Manual


 
www.desatech.com
108860-01D24
INSPECTING BURNERS
Check pilot ame pattern and burner ame patterns often.
PILOT ASSEMBLY
The pilot assembly is factory preset for the proper ame. Altera-
tions may have occurred during shipping and handling. The pilot
is located on the back right hand side of the burner.
The ame must envelope 1/4" of top of the ignitor/sensor and
grounding stem.
If your pilot assembly does not meet these requirements:
Turn the adjustment screw marked PILOT clockwise to decrease
or counterclockwise to increase the ame to proper size (see
Figure 48, page 23). Do not remove the adjustment screw.
see Troubleshooting, page 26
BURNER FLAME PATTERN
Burner ames will be steady; not lifting or oating. Flame patterns
will be different from unit to unit and will vary depending on instal-
lation type and weather conditions.
If the vent conguration is installed incorrectly, the ames will lift
or "ghost". This can be dangerous. Inspect the ames after instal-
lation to ensure proper installation and performance.
Figure 51 shows a typical ame pattern.
If burner ame pattern differs from that described:
turn replace off (see To Turn Off Gas to Appliance, page 23)
see Troubleshooting, page 26
Figure 51 - Typical Flame Pattern
OPERATING FIREPLACE
Continued
Pilot Burner
Ignitor/Sensor
Figure 50 - Correct Pilot Flame Pattern
Sensing Rod
Locate the blower controls by opening the lower louver panel
on the replace. Blower controls are located on the left side of
the switch bracket to the left just inside the louver panel.
The BK manual blower and the BKT thermostatically-controlled
blower have an ON setting and an OFF setting. The blower
will only run when the switch is in the ON position. In the OFF
position, the blower will not operate.
Note for BKT Only: If you are using BKT blower with optional
thermostat (wall mounted or remote control) for the replace,
your replace and blower will not turn on and off at the same
time. The replace may run for several minutes before the blower
turns on. After the heater modulates to the pilot position, the
blower will continue to run. The blower will shut off after the
rebox temperature decreases.
The blower helps distribute heated air from the replace. Peri-
odically check the louvers of the rebox and remove any dust,
dirt, or other obstructions that will hinder the ow of air.
OPERATING OPTIONAL
