Desa (V)T32EN Indoor Fireplace User Manual


 
www.desatech.com
108860-01D 23
OPERATING FIREPLACE
FOR YOUR SAFETY READ
BEFORE LIGHTING
TO TURN OFF GAS

1. Turn off the wall switch.
2. Turn off all electric power to the appliance if service is to
be performed.
3. Open lower louver panel.
4. Turn equipment shutoff valve clockwise to OFF. Do
not force.
5. Close lower louver panel.
WARNING: If you do not follow these instructions

damage, personal injury or loss of life.
A. This appliance has a pilot which must be lighted by hand.
When lighting the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area
for gas. Be sure to smell next to the oor because some gas
is heavier than air and will settle on the oor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone
in your building.
Immediately call your gas supplier from a neighbor's
phone. Follow the gas supplier's instructions.
C. Do not use this appliance if any part has been under water.
Immediately call a qualied service technician to inspect
the appliance and to replace any part of the control system
and any gas control which has been under water.
LIGHTING



will also be present. Open damper or window to vent
smell. This will only last a few hours.
1. STOP! Read the safety information, above.
2. Turn off all electric power to the appliance.
3. Turn wall switch to the OFF position.
4. Open lower louver panel.
5. Turn equipment shutoff valve clockwise to the OFF
position (see Figure 48). Do not force.
6. Wait ve (5) minutes to clear out any gas. Then smell for
gas, including near the oor. If you smell gas, STOP! Follow
“B” in the safety information above. If you don’t smell gas,
go to the next step.
7. Turn equipment shutoff valve counterclockwise to
the ON position. Do not force.
8. Close lower louver panel.
9. Turn on all electric power to the appliance.
10. Turn the wall switch to the ON position.
Figure 48 - Turning Equipment Shutoff Valve to the OFF
Position
Equipment Shutoff Valve
Adjustment Screw
Figure 49 - Pilot
Sensing
Rod
Pilot Burner
Ignitor
OPTIONAL REMOTE
OPERATION
Note: The WRC receiver and hand-held remote control kit
must be purchased separately (see Accessories, page 29). Follow
installation instructions on page 22.
1. Turn equipment shutoff valve to ON position. You can
now turn the burner on and off with the hand-held remote
control unit.
IMPORTANT: Be sure to press the ON/OFF buttons on the
hand-held remote control unit for up to 3 seconds to assure
proper operation.
2. Press the ON/OFF button to turn the burner on and off.
11. Visually locate the pilot. The ignitor should begin to spark and
the main burner should ignite once ame appears at pilot.
If lighting the appliance for the rst time each season,
it may take several attempts before the supply gas can
reach the pilot and main burners.
If the appliance will not stay lit after several attempts,
follow the instructions To Turn Off Gas To Appliance, and
call your service technician or gas supplier.