Desa VN20BTB Electric Heater User Manual


 
www.desatech.com
124002-01C 23
SPECIFICATIONS
HDB20PT, WMP20A
10,000/20,000 Btu/Hr (Variable)
Type Gas: Propane/LP Only
Ignition: Piezo
Pressure Regulator Setting: 8" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
HDB30PT
15,000/30,000 Btu/Hr (Variable)
Type Gas: Propane/LP Only
Ignition: Piezo
Pressure Regulator Setting: 8" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
GWP20TB, MP20T, VP20BTB
10,000/20,000 Btu/hr (Variable)
Propane/LP Gas
Electronic Ignition
Pressure Regulator Setting: 8" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
GWP30TB, MP30T, VP30BTB
15,000/30,000 Btu/hr (Variable)
Propane/LP Gas
Electronic Ignition
Pressure Regulator Setting: 8" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 14" W.C., Minimum - 11" W.C.
HDB20NT, WMN20A
10,000/20,000 Btu/Hr (Variable)
Type Gas: Natural Only
Ignition: Piezo
Pressure Regulator Setting: 3" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
HDB30NT
15,000/30,000 Btu/Hr (Variable)
Type Gas: Natural Only
Ignition: Piezo
Pressure Regulator Setting: 3" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
GWN20TB, MN20T, VN20BTB
10,000/20,000 Btu/hr (Variable)
Natural Gas
Electronic Ignition
Pressure Regulator Setting: 3" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
GWN30TB, MN30T, VN30BTB
15,000/30,000 Btu/hr (Variable)
Natural Gas
Electronic Ignition
Pressure Regulator Setting: 3" W.C.
Inlet Gas Pressure (in. of water):
Maximum - 10.5" W.C., Minimum - 4" W.C.
REPLACEMENT PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
PARTS UNDER WARRANTY
Contact authorized dealers of this product. If
they can’t supply original replacement part(s),
call DESA Heating, LLC at 1-866-672-6040.
When calling DESA Heating, LLC, have
ready:
your name
your address
model and serial numbers of your heater
how heater was malfunctioning
purchase date
Usually, we will ask you to return the part to
the factory.
PARTS NOT UNDER WARRANTY
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), either contact your nearest Parts
Central (see page 27) or call DESA Heating,
LLC at 1-866-672-6040 for referral informa-
tion. A list of authorized dealers can be found
by visiting www.desatech.com.
When calling DESA Heating, LLC, have
ready:
model and serial numbers of your heater
the replacement part number