OWNER’S MANUAL
GAS SUPPLY TESTING
Note:
This section is intended as a guide for
qualified technicians installing gas to this
appliance.
Do not connect appliance before pressure
testing gas piping. Damage to gas valve may
result and an unsafe condition may be caused.
IMPORTANT:
The appliance and its indi-
vidual shut-off valve must be disconnected
from the gas supply piping system during
any pressure testing of that system at test
pressures in excess of 1/2 psig (3.5 kPa).
The Gas Control Valve is secured to the
burner pan assembly underneath the front
ledge.
GAS RATINGS
TYPE OF GAS: NATURAL PROPANE/LP
MAX. INPUT
RATING (Btu/hr): 12,000 12,000
MANIFOLD
PRESSURE: 3.5 in. W.C. 10.0 in. W.C.
* MIN. SUPPLY
PRESSURE: 4.5 in. W.C. 7.0 in. W.C.
MAX. SUPPLY
PRESSURE: 10.5 in. W.C. 13.0 in. W.C.
*For the purpose of input adjustment
Figure 17 - 1/8" Plugged Tapping Location
INSTALLATION
Continued
Installing 9-Volt Battery in Hand-
Held Remote Control Unit
1. Remove battery cover on back of re-
mote control unit.
2. Attach terminal wires to the battery
(not included). Place battery into the
battery housing.
Note:
Only use alka-
line battery.
3. Replace battery cover onto remote con-
trol unit.
Figure 16 - Installing Battery in Hand-
Held Remote Control Unit
Battery
Cover
9-Volt
Battery
Terminal
Wires
Remote
Control Unit
Battery
Housing
TH
TP
TH
TP
R
O
B
E
R
T
S
H
A
W
IN
P
I
L
O
T
ON OFF
PILOT ADJ
Gas Shut
Off Valve
Red Surface Indicates
For Propane Use Only
Air Shutter
Flexible
Gas Line
DO NOT
KINK
Coupling
Pilot
Adjustment
Cap
1/8" NPT
Plugged
Tapping
A 1/8" NPT plugged tapping is provided on
the Gas Control Valve for a test gauge
connection immediately upstream of the
gas supply connection to the appliance (see
Figure 17).
Continued