INSTALLING DAMPER CLAMP ACCESSORY
FOR VENTED OPERATION
Note: When used as a vented decorative, appliance must be installed only
in a solid-fuel burning fireplace with a working flue and constructed of non
-
combustible material.
If your heater is a non-thermostatically-controlled model, you may use this
heater as a vented product. There are three reasons for operating your
heater in the vented mode.
1. The fireplace does not meet the clearance to combustibles requirements
for vent-free operation.
2. State or local codes do not permit vent-free operation.
3. You prefer vented operation.
If reasons number 1 or 2 above apply to you, you must permanently open
chimney flue damper. You must install the damper clamp accessory (to order,
see Accessories, page 27). This will insure vented operation (see Figure
10). The damper clamp will keep damper open. Installation instructions are
included with clamp accessory.
See chart below for minimum permanent flue opening you must provide.
Attach damper clamp so the minimum permanent flue opening will be
maintained at all times.
Area of Various Standard
Round Flues
Diameter (ins.) Area (sq. ins.)
5" 20 sq. inches
6" 29 sq. inches
7" 39 sq. inches
8" 51 sq. inches
Chimney Minimum Permanent
Height (ft.) Flue Opening (sq. ins.)
6' to 15' 39 sq. inches
15' to 30' 29 sq. inches
INSTALLATION
Continued
INSTALLING HEATER ASSEMBLY
WARNING: If installing in a sunken fireplace, special care is needed.
You must raise the fireplace floor to allow access to heater control panel.
This will insure adequate air flow and guard against sooting. Raise fireplace
floor with non
-combustible material. Make sure material is secure.
CAUTION: Do not pick up heater assembly by logs. This could dam-
age
unit. Only handle assembly by grates.
IMPORTANT: Make sure the heater burners are level. If heater is not level,
heater will not work properly.
Installation Items Needed
control cover kit (provided with heater)
approved flexible gas hose and fittings (provided with heater) (if allowed
by local codes)
sealant (resistant to propane/LP gas, not provided)
Note: Install optional GHRCTA Receiver and Hand-Held Remote Control Kit
(see Accessories, page 27) before installing gas log heater (Remote-Ready
Models Only). See installation instructions included with the kit.
1. Apply pipe joint sealant lightly to male threads of gas fitting (not pro
-
vided). Connect approved flexible gas hose to inlet side of gas control
(see Figure 11).
2. Position heater assembly in fireplace.
3. Connect to gas supply. See Connecting To Gas Supply, (see Figure
12, page 11).
INSTALLATION
Installing Damper Clamp Accessory for Vented Operation
Installing Heater Assembly
Figure 11 - Attaching Flexible Gas Hose to Heater Gas Regulator
Gas Control
Flexible Gas Hose
(if allowed by local
codes)
Figure 10 - Attaching Damper Clamp
Damper
Damper Clamp
Damper
Manufactured Fireplace
Masonry Fireplace
Damper Clamp
Damper