Desa VFRMV18PA Electric Heater User Manual


 
114745-01
For more information, visit www.desatech.com
14
OPERATING HEATER
OPERATING HEATER (REMOTE-READY MODELS)
For Your Safety Read Before Lighting
Lighting Instructions
WARNING: If you do not follow these instructions exactly, a
fire or explosion may result causing property damage, personal
injury or loss of life.
A. This appliance has a pilot which must be lighted by hand. When lighting
the pilot, follow these instructions exactly.
B. BEFORE LIGHTING smell all around the appliance area for gas. Be
sure to smell next to the floor because some gas is heavier than air
and will settle on the floor.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electric switch; do not use any phone in your build-
ing.
Immediately call your gas supplier from a neighbor’s phone. Follow
the gas supplier’s instructions.
If you cannot reach your gas supplier, call the fire department.
C. Use only your hand to push in or turn the gas control knob. Never use
FOR YOUR SAFETY READ
BEFORE LIGHTING
REMOTE-READY MODELS
tools. If the knob will not push in or turn by hand, don’t try to repair it,
call a qualified service technician or gas supplier. Force or attempted
repair may result in a fire or explosion.
D. Do not use this appliance if any part has been under water. Immedi
-
ately call a qualified service technician to inspect the appliance and to
replace any part of the control system and any gas control which has
been under water.
5. Wait five (5) minutes to clear out any gas. Then smell for gas, including
near the floor. If you smell gas, STOP! Follow “B” in the safety informa
-
tion, starting in column 1 of this page. If you don’t smell gas, go to the
next step.
6. Press in and turn control knob counterclockwise to the PILOT
position. Press in control knob for five (5) seconds (see Figure 17).
Note: You may be running this heater for the first time after hooking up
to gas supply. If so, the control knob may need to be pressed in for 30
seconds or more. This will allow air to bleed from the gas system.
7. With control knob pressed in, press and release ignitor button. This
will light pilot. The pilot is attached to the front burner. If needed, keep
WARNING: Burners will come on automatically within one
minute when the selector switch is in the ON position after the
pilot is lit.
1. STOP! Read the safety information, starting in column 1, of this
page.
2. Make sure equipment shutoff valve is fully open.
3. Set selector switch in the OFF position.
4. Press in and turn control knob clockwise
to the OFF position
(see Figure 17).
LIGHTING INSTRUCTIONS
WARNING
If fireplace has glass doors, never operate this heater with
glass doors closed. If you operate heater with doors closed,
heat buildup inside fireplace will cause glass to burst. Also if
fireplace opening has vents at the bottom, you must open the
vents before operating heater.
You must operate this heater with a fireplace screen in place.
Make sure fireplace screen is closed before running heater.
NOTICE: During initial operation of new heater, burning logs will
give off a paper-burning smell. Orange flame will also be present.
Open damper or window to vent smell. This will only last a few
hours.
Note: Home owners generally prefer to operate their heater with the chimney
damper closed. This will put all the heat into the room. However, there may
be times you will desire the full flames of the HI heat setting but will find the
heat output excessive. You can open the chimney damper (if you have one)
fully or partially to release some of the heat.
WARNING: Damper handle will be hot if heater has been
running.
Figure 17 - Control Knob and Ignitor Button Location,
Manual Controlled








114745-01