Desa (V)DVF36TCRP(E) Indoor Fireplace User Manual


 
www.desatech.com
112108-01C30
REMEDY
1. Replace ignitor if wire is prop-
erly connected and you have
no spark
2. Using a match, light pilot. If pi-
lot lights turn off pilot and push
piezo again. If pilot lights, an
improper gas/air mixture cause
improper lighting and a longer
purge period is recommended. If
pilot will not light, check gap at
electrode and pilot. Gap should
be 1/8" for strong spark. If elec-
trode is okay, replace pilot
3.  Check fuel supply
and contact local propane/LP
supplier if low.
  Check for
kinked or bent hoses. Consult
pipe tter or plumber.

1. Defective ignitor
2. Defective pilot or misaligned
electrode at pilot
3. No or low gas pressure

When ignitor button is pressed,
there is no spark at pilot
TROUbLESHOOTING
Continued
REMEDY
1.  Check fuel supply
and contact local propane/LP
supplier if low.
  Check for
kinked or bent hoses. Consult
pipe tter or plumber.
2. Repeat lighting procedure
several times to purge air from
lines. If unit will still not light,
contact a qualied service and
repair technician
3. Remove debris and dirt, in-
spect and clean other possible
obstructions
4. Replace control valve
5. Contact a qualied technician
to replace pilot line
6. Check that main power is on
and all wire connections are
made correctly to ignition
module

1. No or low gas pressure
2. Air in gas line
3. Construction debris clogging
main orice
4. Control valve knob not
opening
5. Kinked pilot line
6. No power to unit or ignition
module/power transformer is
bad

Ignitor will not spark or burner
will not light
ELECTRONIC IGNITION SYSTEM