Desa (V)DVF36TCRP(E) Indoor Fireplace User Manual


 
www.desatech.com
112108-01C 17
VENTING INSTALLATION
INSTRUCTIONS
Continued
Figure 29 - Vertical Rigid Venting
Conguration With No Horizontal Run

V = 40' max.
HIGH ALTITUDE INSTALLATION
Your DESA direct-vent replace has been tested
and approved for elevations from 0-2,000 feet and
certied for elevations from 0-5,000 feet.
Fireplaces for High Altitude (models ending in
HA) are for installation above 4,000 feet only.
These replaces are equipped with parts specic
for higher altitudes. IMPORTANT: These re-
places can NOT be converted to propane/LP gas.
When installing a non-high altitude replace at an
elevation above 2,000 feet (USA), you may need to
decrease the input rating by changing the existing
burner orice to a smaller size. Reduce input 4%
for each 1,000 feet above sea level. Check with
your local gas company for proper orice size
identication.
When installing this fireplace at an elevation
above 4,500 feet (Canada), check with local
authorities.
Consult with your local gas company to help de-
termine the proper orice size and identication
for your location.
Components and parts must be ordered by part
number through your local dealer or distributor.
IMPORTANT: For horizontal installations
above 2,000 feet, it is recommened that a 12"
extension pipe be added before starter elbow
(see Figure 30).



 
VKR-58 Roof Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Flue Restrictor,
Vertical High Wind Termination,
2' Pipe, 4' Pipe, Wall Firestop,
Storm Collar, Roof Flashing
[0/12 - 6/12], 26 Screws)
VKB-58 Basement Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
4' Pipe, 90° Elbow, 20 Screws)
VKS-58 Snorkel Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
36" Snorkel Termination, 4' Pipe,
1' Pipe, 90° Elbow, 26 Screws)
VKG-58 Ground Floor Vent Kit, Galvanized
(Includes: 45° Elbow, 7"-12"
Adjustable Pipe, Wall Firestop,
Horizontal Square Termination,
16 Screws)
P58-48 48" Section Double Wall Pipe,
Galvanized
P58-36 36" Section Double Wall Pipe,
Galvanized
P58-24 24" Section Double Wall Pipe,
Galvanized
P58-12 12" Section Double Wall Pipe,
Galvanized
P58-6 6" Section Double Wall Pipe,
Galvanized
PA58-712 Adjustable 7"-12" Section Double
Wall Pipe, Galvanized
FPA58-6 6" Dura Vent Collar to FMI Pipe
Adaptor
Figure 30 - Recommended 12" Extension
for High Altitude Installation
45° Starter
Elbow
Note: Install
restrictor into inner
collar of replace
as shown.
45° Starter
Elbow
12"
Extension