Desa CF26PTA Indoor Fireplace User Manual


 
www.desatech.com
11389
6-01A 9
BUILT-IN FIREPLACE
INSTALLATION
Built-in installation of this fireplace involves in-
stalling fireplace into a framed-in enclosure. This
makes the front of fireplace flush with wall. Follow
the instructions below to install the fireplace in this
manner. If installing a built-in mantel above the
fireplace, you must follow the clearances shown
in Figure 9, page 11. If using for built-in instal-
lation off of the floor, follow clearances shown
in Figure 4.
Actual Framing
Height 26" 26
7
/
8
"
Front Width 26
3
/
4
" 26
7
/
8
"
Depth 9
1
/
2
" 10
1
/
2
"
Bottom 3/4" 3/4"
1. Frame in rough opening. Use dimensions shown
in Figure 6 for the rough opening.
If installing in a corner, use dimensions shown
in Figure 7 for the rough opening. The height
is 26
1
/
8
" which is the same as the wall opening
above.
2. An optional blower accessory is available (see
Accessories, page 32). There are two options
for connecting blower to electrical source.
Option one: Have a licensed electrician install
a properly grounded, three-prong 120-volt
electrical outlet at fireplace location. Locate
outlet inside the framed enclosure. Blower
power cord will plug into this outlet.
INSTALLATION
Continued
An optional blower kit is available from your
dealer. See Accessories, page 32. If planning to use
blower, locate fireplace near an electrical outlet.
Note: When installing fireplace directly on carpet
-
ing, tile or other combustible material, other than
wood flooring, the fireplace shall be installed on a
metal or wood panel extending the full width and
depth of the fireplace.
36
5
/8"
25
7
/8
"
51
3
/
4
"
26
7
/8
"
Figure 7 - Rough Opening for Installing
in Corner
26
7
/
8
"
26
7
/
8
"
3/4" Off
The Floor
Minimum
10
1
/
2
"
Figure 6 - Rough Opening for Installing
in Wall
Figure 5 - Mounting Clearances As
Viewed From Front of Fireplace Shown
with Optional Mantel
Figure 4 - Mounting Clearances As
Viewed From Front of Fireplace Shown
Built In The Wall
6"
Minimum
From
Sides Of
Fireplace
Left
Side
CEILING
42" Minimum
FLOOR
Right
Side
Top Of
Mantel Can
Be Flush
With Wall
Left
Side
CEILING
Right
Side
42"
Minimum
0" Minimum Clearance To Top Surface Of
Carpeting, Tile Or Other Combustible Material
0" Minimum Clearance To Top Surface Of
Carpeting, Tile Or Other Combustible Material