8
103252
OPERATION
!
WARNING
Review and understand the warnings in the Safety
Information Section. They are needed to safely operate this
heater. Follow all local codes when using this heater.
To Start Heater
1. Follow all ventilation and safety information.
2. Fill fuel tank with kerosene or No. 1 fuel oil.
3. Attach fuel cap.
4. Plug power cord of heater into 220 volt/60 hertz grounded outlet. Use an
extension cord if needed. Use only a three-prong, grounded (earthed) exten-
sion cord.
Extension Cord Wire Size Requirements
Up to 100 feet (30.5 meters) long, use 16 AWG (1.0 mm
2
) rated cord
101 to 200 feet (30.8 to 61 meters) long, use 14 AWG (1.5 mm
2
) rated cord
Heater will start when power cord is plugged into outlet. If not, push in burner
control reset button (see Figure 4).
Figure 4 - Burner Control Reset Button
Burner
Control
Reset
Button
To Stop Heater
1. Unplug power cord from outlet.
To Restart Heater
1. Wait 2 minutes after stopping heater.
2. Repeat steps under To Start Heater, above.