Desa RK150 Electric Heater User Manual


 
6
103252
THEORY OF
OPERATION
The Fuel System: The air pump forces air through the air line. The air is then
pushed through the burner head nozzle. This air causes fuel to lift from the tank.
A ne mist of fuel is sprayed into the combustion chamber.
The Air System: The motor turns the fan. The fan pushes air into and around
the combustion chamber. This air is heated and provides a stream of clean, hot air.
The Ignition System: The electronic ignitor sends voltage to the spark plug.
The spark plug ignites the fuel and air mixture.
The Burner Control System: This system causes the heater to shut down if
the ame goes out.
THEORY CUTAWAY
PFA/OV 003
Fuel
Filter
Air For Fuel
System
Air For Combustion
And Heating
Combustion
Chamber
Air
Intake
Filter
Clean
Heated
Air Out
Fuel
Tank
Burner
Head
Spark
Plug
Motor
Fan
Electronic
Ignitor
Air Line
To Burner
Nozzle
Air Pump
Cool
Air
In
Air
Output
Filter
Figure 3 - Cross Section Operational View